• Note d'application

Acetaminophen

Acetaminophen

  • Waters Corporation

This is an Application Brief and does not contain a detailed Experimental section.

Abstract

This application brief demonstrates analysis of acetaminophen.

Introduction

The compound analyzed in this study is acetaminophen.

Experimental

Conditions

Column:

Xterra RP18 4.6 x 50 mm, 5 μm

Part Number:

186000492

Mobile phase :

pH 3.0: H2O/ACN/100 mM NH4COOH, pH 3.0 15:75:10

pH 7.0: H2O/ACN/100 mM NH4HCO3, pH 7.0 65:25:10

pH 10.0 H2O/ACN/100 mM NH4HCO3, pH 10.0 87.5:2.5:10

Flow rate:

1.0 mL/min

Injection volume:

5 μL of 250 μg/m

Temperature:

30 °C

Detection:

UV @ 270 nm

Instrument:

Alliance 2695, 2996 PDA

Mobile Phase pH

USP Tailing Factors

3.0

1.25

7.0

1.21

10.0

1.06

Results and Discussion

Featured Products

WA20738.003, June 2002