GlycoWorks RFMS Clean-up Module Group

SKU: 186008913
GlycoWorks RFMS Clean-up Module

GlycoWorks RFMS Clean-up Module | 186008913


Streamline Purchasing with Customized Quotes

Streamline Purchasing with Customized Quotes

Shop on Waters.com and add items to your cart

Navigate to the Shopping Cart

Select Request a Quote to get your quote instantly


Product Description

The GlycoWorks RapiFluor-MS Clean-up Module is used to support existing RapiFluor-MS (RFMS) customers who are looking to order just the sample clean up module alone. This is the exact module shipped with the GlycoWorks RapiFluor-MS kits. Enough materials are provided to clean-up 96 samples. The GlycoWorks RFMS Clean-up Module contains:

 

(4) 5 ml/vial Elution Buffer (200mM Ammonium Acetate 95/5 Water/ACN pH 7)

(4) 8 ml/vial Sample Diluent (DMF/ACN Mixture)

(1) GlycoWorks HILIC µElution Plate

Specifications

  • UNSPSC

    41116104

  • Application

    Glycan

  • Brand

    GlycoWorks

  • Product Type

    Application Kits

Hazaradous Material This product contains hazardous material which requires special freight handling. Additional charges may apply.

Product Support

Documents

Documents



What do you want to do?

What do you want to do?
Back To Top Back To Top

GlycoWorks RFMS Clean-up Module

The GlycoWorks RapiFluor-MS Clean-up Module is designed to be used alongside the other GlycoWorks RapiFluor-MS products, so current GlycoWorks clients’ such as yourself who are interested in ordering only the sample cleaning kits are able to do so. The RapiFluor-MS Kits replace tedious and complicated sample collection processes into a streamlined, three-step process, taking under 30 minutes to prep everything.

The GlycoWorks RapiFluor-MS Clean-up Module is included as part of the RapiFluor-MS kits, such as the GlycoWorks RFMS 96-kit sample and has enough materials sent with it to provide clean up for 96 samples.

The GlycoWorks RapiFluor-MS Clean-up module contains vials of Elution Buffer, Sample Diluent, and HILIC µElution Plate. GlycoWorks HILIC µElution Plate is quite effective for removing contaminants like salts and detergents from hydrophilic analytes, such as carbohydrates, prior to mass spectrometry analysis. Given the Clean-Up lab equipment enables elution volumes as low as 25 µL, it eliminates any time-consuming evaporation steps.

Given the nature of the materials, the module components should be handled with care and are marked as hazardous materials for any transport purposes as well.

You can learn more about GlycoWorks RFMS Clean-up Module and similarly linked products on our shop for lab equipment; you can also explore our website for reviewing and referring to other products available in our catalog.

Linked to the GlycoWorks RFMS Clean-up Module, you should also check out the GlycoWorks RapiFluor-MS Labeling Module 24-Sample; it provides a supreme mass spectral response, and as a result, you get an elaborate characterization and valuable information on your samples. At the same time, the Glycoworks RapiFluor-MS N-Glycan Kit-96 sample is used for analyzing released N-glycans in a more streamlined and faster manner. Similar to the 'RFMS Labelling Module 24-Sample', the Glycoworks RapiFluor-MS N-Glycan Kit-96 sample’s unique chemical attributes provide increased fluorescence quantification and supreme mass spectral response. Utilizing the kits, the Glycan analysis becomes much easier and more sensitive.

Are There Any Special Handling And Transport Requirements For GlycoWorks RFMS modules?

Both the Glycoworks RapiFluor-MS 24-Sample and the Glycoworks Rapi-Flour-MS N-Glycan Kit-96 sample need to be handled with care and caution. RFMS 24-Sample is marked as hazardous for transport, whereas the RFMS kit-96 has to be shipped cold. The GlycoWorks RapiFluor-MS Clean-up Module also is shipped with a hazardous material sticker to ensure it is handled with care and caution.