Chemistry |
C18 |
Separation Mode |
Reversed Phase |
Particle Substrate |
Hybrid |
pH Range Min |
1 pH |
pH Range Max |
12 pH |
Maximum Pressure |
18000 psi (1240 Bar) |
Endcapped |
Yes |
Silanol Activity |
Low |
Particle Shape |
Spherical |
Particle Size |
1.7 µm |
Endfitting Type |
Parker-style |
Pore Size |
130 Å |
Format |
Column |
Surface Area |
185 |
System |
UHPLC, UPLC |
Particle Technology |
BEH |
USP Classification |
L1 |
Inner Diameter |
2.1 mm |
Length |
30 mm |
Carbon Load |
18 % |
eCord |
Yes |
UNSPSC |
41115709 |
Brand |
ACQUITY UPLC |
Product Type |
Columns |
Units per Package |
3 pk |
ACQUITY UPLC BEH C18 Column, 130Å, 1.7 µm, 2.1 mm X 30 mm, 3/pk
The ACQUITY UPLC BEH C18 Column is made to address a wide range of chromatographic issues as well as lab and technique needs. The column helps to increase the analysis's resolution, sensitivity, and speed. The ACQUITY UPLC BEH C18 Column can help you achieve a variety of analytical goals, including obtaining ultra-fast analysis, increasing throughput while preserving resolution, or improving resolution while cutting down on analysis time.
The 1.7 µm ACQUITY UPLC BEH C18 sorbent is the most versatile column option for UPLC separations and is the leading column for method development. Due to the analytical column's tri-functional bonding, the ACQUITY UPLC BEH C18 Column is ideally suited to evaluate a variety of analytes and can be utilized as a general method development tool. It makes it possible to attain extremely high and low pH stability for all sorts of analytes.
Utilizing the industry-leading mobile phase pH range (1–12) and high-temperature stability (80 °C) of the ACQUITY UPLC BEH C18 Column, you may obtain exceptional analysis. For high sensitivity MS applications, the tri-functionally bound BEH particle, on which the column is based, provides the widest useable pH range (pH 1–12), improved low pH stability, and ultra-low column bleed. The retention, selectivity, and sensitivity of ionizable chemicals will be directly impacted by the addition of the ACQUITY UPLC BEH C18 Column to your system. Due to the packing materials' special design for use with the ACQUITY UPLC System, the column produces remarkable performance.
To discover all your requirements and demands for conducting tests and analyses in your laboratory, you can shop for lab equipment on our website or by browsing through our comprehensive brochure. The ACQUITY UPLC Protein BEH SEC Column, 125Å, 1.7 µm, 4.6 mm x 150 mm, 1/pk and BEH125 SEC Protein Standard Mix, which is the first commercially available sub-2-m SEC chemistry column and is based on the extremely successful BEH particle technology, may also be of interest to you. With this column, the total system solution will routinely deliver quick, accurate aggregate determinations up to 10 times quicker than conventional HPLC-based SEC methods. It is fully optimized for the analysis of proteins and their aggregates with molecular weights ranging from 1000 to 80,000 Daltons.
What Pressure And pH Range Can The ACQUITY UPLC BEH C18 Column Operate Under?
With safety, the ACQUITY UPLC BEH C18 Column can run at pressures of up to 18000 psi and pH ranges of 1 to 12. (or 1240 Bar).