Chemistry |
C18 |
Separation Mode |
Reversed Phase |
Particle Substrate |
Hybrid |
pH Range Min |
1 pH |
pH Range Max |
12 pH |
Maximum Pressure |
18000 psi (1240 Bar) |
Endcapped |
Yes |
Silanol Activity |
Low |
Particle Shape |
Spherical |
Particle Size |
2.5 µm |
Endfitting Type |
Parker-style |
Pore Size |
130 Å |
Format |
Column |
Surface Area |
185 |
System |
UHPLC, UPLC |
Particle Technology |
BEH |
USP Classification |
L1 |
Inner Diameter |
3 mm |
Length |
75 mm |
Carbon Load |
18 % |
eCord |
Yes |
UNSPSC |
41115709 |
Brand |
XBridge |
Product Type |
Columns |
Units per Package |
3 pk |
XBridge BEH C18 Column, 130Å, 2.5 µm, 3 mm X 75 mm, 3/pk
Utilize the XBridge BEH C18 Column, which was created especially to boost lab throughput to achieve maximum productivity. The XBridge BEH C18 Column will be adequate to satisfy your objectives, whether your objective is to construct a cutting-edge LC/MS assay or a quality control method. The lab equipment improves pH stability, extending the lifetime of the columns and lowering lab costs because fewer pieces of equipment will need to be replaced. You can easily improve column reliability and take advantage of assay robustness with the analytical column. The XBridge BEH C18 Column also provides exceptional peak shape and peak capacity by increasing particle efficiency.
A workhorse for HPLC method development, the sorbent employed in the XBridge BEH C18 Column can be used over the whole range of mobile phase pH. The trifunctionally linked C18 ligand gives you the widest usable pH range, better low pH stability, and extremely little column bleed, making it a universal column for the majority of HPLC separations.
When compared to columns with standard packing materials, the XBridge packing exhibits very little retention loss or peak shape deterioration because it uses specialized techniques for bonding and end-capping and is ligand stable at low pH. As a result, the XBridge BEH C18 Column provides remarkable column longevity without the need to sterically inhibit the stationary phase. The XBridge BEH C18 Column, which combines the BEH particle production method with cutting-edge bonding and end-capping technologies to create a highly sought-after piece of lab equipment, is also extremely durable under high pH settings.
We recommend that you also use the XBridge BEH C18 XP VanGuard Cartridge, 130Å, 2.5 µm, 2.1 mm X 5 mm, 3/pk in conjunction with the column in order to increase its lifetime and improve the accuracy of the results. The cartridge is made using the same packing materials that are present in the column, making these two pieces of lab equipment well-matched. It works by removing any unwanted chemical or particulate contaminants from the mobile phase.
Across What pH Range Does The XBridge BEH C18 Column Operate?
The Waters XBridge BEH C18 Column listed here is able to work well across the broad 1-12 pH range.
What Is The Maximum Pressure That The XBridge BEH C18 Column Can Tolerate?
The recommended maximum pressure for the XBridge BEH C18 Column is 18,000 psi (1240 Bar).