BioResolve RP mAb Columns contain 2.7-μm superficially-porous-silica particles having an average pore diameter of 450Å. The particles are functionalized with a proprietary polyphenyl bonding process that was specifically designed for LC or LC-MS analyses of intact IgG monoclonal antibodies and their fragments. This P/N also includes one vial of the Intact mAb Mass Check Standard (P/N 186006552) and one vial of the mAb Subunit Standard (P/N 186008927).
Separation Mode |
Reversed Phase |
Particle Size |
2.7 µm |
Pore Size |
450 Å |
UNSPSC |
41115709 |
Brand |
BioResolve |
Product Type |
Columns |
Units per Package |
1 pk |
BioResolve RP mAb Polyphenyl Column, 450Å, 2.7 µm, 3 mm X 100 mm, 1/pk with Intact mAb and mAb Subunit Standards
Reverse-phase chromatography can be a powerful analytical tool for protein analysis, but you need an instrument that can handle the demanding chromatographic conditions presented by RP techniques. That’s where the BioResolve RP mAb Polyphenyl Column comes into consideration. This incredible reverse-phase column offers an innovative solution for the characterization of proteins, as it utilizes a novel phenyl bonding and solid-core technology that will help you greatly improve chromatographic resolution at higher flow rates. Plus, if you’d like to protect your BioResolve RP mAb Polyphenyl Column from contaminants, you can do so with VanGuard column protection technology from Waters. Upgrade your protein analyses with the help of the BioResolve RP mAb Polyphenyl Column today.
At the heart of the BioResolve RP mAb Polyphenyl Column is a collection of particles that are functionalized with the novel phenyl bonding process mentioned earlier. This process is specifically designed for LC or LC-MS analyses of intact IgG monoclonal antibodies and their fragments. But to properly perform correctly with mAb separations, each and every BioResolve RP mAb Polyphenyl Column must undergo strict QC testing with both the Inact mAb Mass Check Standard and mAb Subunit Standard. We’ve included one vial of each standard free of charge with this column, as it’s very important for you to verify LC-MS and LC system and instrument performance before moving forward with your crucial analyses.
Speaking of crucial mAb analyses, how can you protect your BioResolve RP mAb Polyphenyl Column from contamination?
With the BioResolve RP mAb Polyphenyl VanGuard Cartridge. This guard cartridge seamlessly integrates into your existing analytical workflow to provide enhanced protection against column contamination. Plus, when you’ve noticed that the cartridge is becoming worn by use, you can replace it with another genuine guard cartridge from Waters.
At Waters, we have so much more than just BioResolve RP mAb Polyphenyl Columns to provide accurate quantitation of mAbs and their fragments. We also have quality control reference materials, lab informatics, solution kits and so much more. You need only shop lab equipment to discover all of our incredible products and resources.
How Can I Test the BioResolve RP mAb Polyphenyl Column for Performance?
You can test the BioResolve RP mAb Polyphenyl Column for performance with the Intact mAb Mass Check Standard (P/N 186006552) and the mAb Subunit Standard (P/N 186008927).