BioResolve RP mAb Columns contain 2.7-μm superficially-porous-silica particles having an average pore diameter of 450Å. The particles are functionalized with a proprietary polyphenyl bonding process that was specifically designed for LC or LC-MS analyses of intact IgG monoclonal antibodies and their fragments. This Part Number contains (3) VanGuard Cartridges as well as an included VanGuard Universal Cartridge Holder (P/N 186007949).
Separation Mode |
Reversed Phase |
Particle Size |
2.7 µm |
Pore Size |
450 Å |
UNSPSC |
41115709 |
Brand |
BioResolve |
Product Type |
Guards |
Units per Package |
3 pk |
BioResolve RP mAb Polyphenyl VanGuard Cartridge w/ Holder, 450Å, 2.7 µm, 2.1 mm X 5 mm, 3/pk
You already have enough to think about when developing or performing mAb separations. The last think you want to think about is column contamination after repeated use. Even with proper sample purification procedures followed, there’s still a chance your column can become fouled over time by contaminants in the mobile phase stream. To overcome this obstacle, we’re happy to provide the BioResolve RP mAb Polyphenyl VanGuard Cartridge w/ Holder. This all-in-one column protection solution seamlessly incorporates into your existing workflow to provide enhanced protection and extend your column’s overall lifetime. Simply add the BioResolve RP mAb Polyphenyl VanGuard Cartridge to your lab’s procurement list or order one for yourself today.
The main goal of the BioResolve RP mAb Polyphenyl VanGuard Cartridge is to remove contaminants from your analytical workflow as they move through the cartridge. Again, even though proper sample purification procedures remove most of the contaminants, there could still be contaminants lingering in the mobile phase stream. To prevent those contaminants from negatively affecting your analytical column and in turn, your data, this cartridge filters out the contaminants and removes them. This cartridge is also reusable and when it becomes worn, you can replace it with another genuine guard cartridge from Waters.
Upholding chemical and mechanical stability is also at the forefront of the BioResolve RP mAb Polyphenyl VanGuard Cartridge. This guard cartridge offers the same inner diameter and pH range as the BioResolve RP mAb Polyphenyl Column, providing a stable column protection solution that understands the risks and conditions involved in chromatography. Plus, this cartridge comes with the VanGuard Universal Cartridge Holder (P/N 186007949).
Before performing any mAb separations, it’s also important to verify LC-MS system performance. To do so, we recommend using the Intact mAb Mass Check Standard. This specially formulated standard is designed to be used for routine MS optimization and analytical setup.
Once you’ve added the BioResolve RP mAb Polyphenyl Column to your cart, make sure to shop lab equipment to see all of the other incredible products and resources available at Waters Corporation. We’re passionate about providing the items you need to be successful in the lab.
How Many Cartridges Come with the BioResolve RP mAb Polyphenyl VanGuard Cartridge?
Three BioResolve RP mAb Polyphenyl VanGuard Cartridges are included with this item.