Chemistry |
C18 |
Separation Mode |
Reversed Phase |
Particle Substrate |
Hybrid |
pH Range Min |
1 pH |
pH Range Max |
12 pH |
Maximum Pressure |
6000 psi (415 Bar) |
Endcapped |
Yes |
Bonding Technology |
MS C18 |
Silanol Activity |
Low |
Particle Shape |
Spherical |
Particle Size |
3.5 µm |
Endfitting Type |
Waters |
Pore Size |
125 Å |
Format |
Column |
Surface Area |
175 |
System |
HPLC |
USP Classification |
L1 |
Inner Diameter |
2.1 mm |
Length |
30 mm |
Carbon Load |
16 % |
UNSPSC |
41115709 |
Brand |
XTerra |
Product Type |
Columns |
Units per Package |
1 pk |
XTerra MS C18 Column, 125Å, 3.5 µm, 2.1 mm X 30 mm, 1/pk
The XTerra MS C18 Column, which is suitable for Mass Spectrometry (MS) applications, has big peak capacities, crisp peak forms, and good sensitivity. The XTeraa MS C18 Column has one of the longest column lives over a wide pH range (1–12) by utilizing the tri-functional bonding chemistry of the XTerra particles, especially when compared to traditional silica-based columns. Along with the column's ability to deliver the highest throughput with exceptional resolution and extremely low column bleed, several qualities are mentioned.
The analytical column is an all-purpose, hybrid-based, reversed-phase C18 column that has been developed to be suitable for a number of mass spectrometry applications. When compared to a silica-based column, the first-generation XTerra MS C18 Column can offer improved pH stability. The XTerra MS C18 Column is created with ultrapure reagents, much like all other lab equipment sold as being made by Waters, guaranteeing the control of the chemical composition and purity of the hybrid particle. Every stage of the production process is meticulously monitored, controlled, and done within very strict tolerances. To ensure that you only receive the highest caliber lab supplies, each column is additionally put through an individual test.
The particles used in the XTerra packing materials are created using Waters Hybrid Particle Technology and include both organic (organosiloxane) and inorganic (silica) components, providing a potent combination with the benefits of both. In contrast to reversed-phase packing materials made of silica, the XTerra MS C18 column can offer you exceptional separation efficiency and enhanced pH stability in your lab results thanks to hybrid technology. You can shop for lab equipment from the website, as well as contact them with any questions you might have. You can contact a member of our staff at one of our many offices across the world with these questions and concerns.
Additionally, we advise you to look into the XTerra MS C18 VanGuard Cartridge, 125Å, 3.5 µm, 2.1 mm X 5 mm, 3/pk. These cartridges are intended to improve the performance and lifespan of analytical columns by eliminating particulates from the mobile phase stream. All 2.1 mm and 3.0 mm I.D. XTerra MS C18 analytical columns with 3.5 µm sorbent particles are protected by this cartridge.
How Much Pressure and What pH Range Can The XTerra MS C18 Column Handle?
The XTerra MS C18 Column can operate at pressures of up to 6000 psi and has a pH range of 1 to 12. (or 415 Bar).