SKU: 186000400
XTerra MS C18 Column, 125Å, 3.5 µm, 2.1 mm X 50 mm, 1/pk

XTerra MS C18 Column | 186000400


Streamline Purchasing with Customized Quotes

Streamline Purchasing with Customized Quotes

Shop on Waters.com and add items to your cart

Navigate to the Shopping Cart

Select Request a Quote to get your quote instantly


Product Description

XTerra MS C18 columns are general purpose, hybrid-based, reversed-phase C18 columns that are designed to be compatible with mass spectrometry applications. These first generation columns provide superior pH stability compared to a silica-based column.

Specifications

  • Chemistry

    C18

  • Separation Mode

    Reversed Phase

  • Particle Substrate

    Hybrid

  • pH Range Min

    1 pH

  • pH Range Max

    12 pH

  • Maximum Pressure

    6000 psi (415 Bar)

  • Endcapped

    Yes

  • Bonding Technology

    MS C18

  • Silanol Activity

    Low

  • Particle Shape

    Spherical

  • Particle Size

    3.5 µm

  • Endfitting Type

    Waters

  • Pore Size

    125 Å

  • Format

    Column

  • Surface Area

    175

  • System

    HPLC

  • USP Classification

    L1

  • Inner Diameter

    2.1 mm

  • Length

    50 mm

  • Carbon Load

    16 %

  • UNSPSC

    41115709

  • Brand

    XTerra

  • Product Type

    Columns

  • Units per Package

    1 pk

Product Support

Documents

Documents



What do you want to do?

What do you want to do?

Related Products

Back To Top Back To Top

XTerra MS C18 Column, 125Å, 3.5 µm, 2.1 mm X 50 mm, 1/pk

Waters Hybrid Particle Technology is used to create the XTerra packing materials, which comprise both inorganic (silica) and organic (organo-siloxane) components, resulting in a potent combination with both benefits. In comparison to silica-based reversed-phase packing materials, this hybrid technology allows the XTerra MS C18 column to give great separation efficiency and improved pH stability in your lab results.

The XTerra MS C18 Column is designed for Mass Spectrometry (MS) applications and features crisp peak forms, high sensitivity, and big peak capacities. The XTerra MS C18 Column has one of the longest column lives over a wide pH range (1 - 12), especially when compared to traditional silica-based columns, thanks to the tri-functional bonding chemistry of the XTerra particles. These characteristics are highlighted in addition to the column's ability to provide maximum throughput with exceptional resolution and little column bleed.

The analytical column is a hybrid-based reversed-phase C18 column that has been created to work with a variety of mass spectrometry applications. When compared to a silica-based column, the XTerra MS C18 Column is a first-generation column that can give greater pH stability. The XTerra MS C18 Column, like all other Waters' lab equipment, is built using ultrapure reagents, ensuring that the chemical composition and purity of the hybrid particle are controlled. Every stage of the production process is meticulously monitored and controlled, and it is carried out within tight tolerances. Each column is also examined individually to ensure that you receive only the highest-quality laboratory equipment.

Add the XTerra MS C18 Column to your laboratory's equipment. Additional goods compatible with the XTerra MS C18 Column can be found on our website, including guards, vials, and elution plates. You can shop for lab equipment directly on the website, as well as contact us with any questions. You can address your questions and concerns to a member of our team in one of our many offices across the world.

Compatible with the XTerra MS C18 Column, you may be interested in XTerra MS C18 VanGuard Cartridge, 125Å, 3.5 µm, 2.1 mm X 5 mm, 3/pk; XTerra MS C18 VanGuard Cartridges are used to extend analytical column lifetime and performance by removing particulate contamination from the mobile phase stream. This cartridge is optimized to protect all 2.1 mm and 3.0 mm I.D. XTerra MS C18 analytical columns containing 3.5 µm sorbent particles.

What pH Range And Pressure Is The XTerra MS C18 Column Able To Withstand?

The pH range of the XTerra MS C18 Column is 1 to 12, with a maximum pressure of 6000 psi (or 415 Bar).