Chemistry |
C18 |
Separation Mode |
Reversed Phase |
Particle Substrate |
Hybrid |
pH Range Min |
2 pH |
pH Range Max |
12 pH |
Maximum Pressure |
6000 psi (415 Bar) |
Endcapped |
Yes |
Bonding Technology |
Shield RP18 |
Silanol Activity |
Low |
Particle Shape |
Spherical |
Particle Size |
5 µm |
Pore Size |
125 Å |
Format |
Sentry Guard Cartridge |
Surface Area |
175 |
System |
HPLC |
USP Classification |
L1 |
Inner Diameter |
3.9 mm |
Length |
20 mm |
Carbon Load |
15 % |
UNSPSC |
41115709 |
Brand |
XTerra |
Product Type |
Guards |
Units per Package |
2 pk |
XTerra Shield RP18 Sentry Guard Cartridge, 125Å, 5 µm, 3.9 mm X 20 mm, 2/pk
In order to improve peak shape performance for highly basic compounds, Waters has developed the XTerra RP18 columns, which are general-purpose, hybrid-based, reversed-phase C18 columns that incorporate Waters' patented embedded polar group technology. These first-generation columns provide superior pH stability compared to a silica-based column. This is why it is crucial to protect the lab equipment from harm to ensure it lasts you a long time. The XTerra Shield RP18 Sentry Guard Cartridge has been designed and developed to perform this task with exceptional efficiency.
The Waters XTerra Shield RP18 Sentry Guard Cartridge is designed to be used with the XTerra Shield columns for reversed-phase Liquid Chromatography. The lab equipment is a single unit that can be attached directly to the inlet side of your analytical XTerra Column. The XTerra Shield RP18 Sentry Guard Cartridge is easy to install and makes sure that your XTerra Shield Column is protected from damaging contaminants, whether chemical or particulate. Its use will enhance and improve the column’s analytical performance by filtering out any chemical and particulate impurities that may be present in the mobile phase stream.
The XTerra Shield RP18 Sentry Guard Cartridge is manufactured under the strictest cGMP, ISO 9001 conditions. In addition to this, to guarantee that the lab equipment will deliver optimal performance and enhance the selectivity, sensitivity, and speed of your analysis, each unit is tested and certified for its use. The same premier materials that are used in the XTerra Shield RP18 Column are used in the making of the XTerra Shield RP18 Sentry Guard Cartridge. This makes the lab equipment ideally suited for the protection of the XTerra Shield RP18 Column.
Like equipment that is marketed as Waters’ manufactured, the XTerra Shield RP18 Sentry Guard Cartridge is manufactured in a cGMP, ISO 9001 certified plant using ultra-pure reagents. In addition to this, each batch of the XTerra Shield RP18 Sentry Guard Cartridge packing material is tested chromatographically with acidic, basic, and neutral analytes. We recommend that you also explore the XTerra Shield RP18 VanGuard Cartridge, 125Å, 5 µm, 3.9 mm X 5 mm, 3/pk.
What Is The Carbon Load Of The XTerra Shield RP18 Sentry Guard Cartridge?
The XTerra Shield RP18 Sentry Guard Cartridge listed here carries a carbon load of 15%.