Chemistry |
C18 |
Separation Mode |
Reversed Phase |
Particle Substrate |
Silica |
pH Range Min |
3 pH |
pH Range Max |
7 pH |
Maximum Pressure |
6000 psi (415 Bar) |
Endcapped |
Yes |
Bonding Technology |
dC18 |
Silanol Activity |
Medium |
Particle Shape |
Spherical |
Particle Size |
3 µm |
Endfitting Type |
Waters |
Pore Size |
100 Å |
Format |
Column |
Surface Area |
330 |
System |
HPLC |
USP Classification |
L1 |
Inner Diameter |
2.1 mm |
Length |
30 mm |
Carbon Load |
12 % |
UNSPSC |
41115709 |
Brand |
Atlantis |
Product Type |
Columns |
Units per Package |
1 pk |
Atlantis dC18 Column, 100Å, 3 µm, 2.1 mm X 30 mm, 1/pk
The Atlantis dC18 column is a versatile, silica-based, reversed-phase C18 column that can be used for polar compound retention, so consider adding it to your collection of lab equipment. Di-functionally bound C18 ligands that have been specially designed for usage with extremely aqueous mobile phases, such as 100% water, are present in the Atlantis dC18 columns.
You will easily achieve the appropriate balance of retention for both polar and non-polar molecules using the Atlantis dC18 column. A universal C18 Column that is LC/MS compatible is also part of the lab equipment. The Atlantis dC18 Column provides greater retention of polar molecules without demonstrating excessive retention of hydrophobic compounds when compared to traditional reversed-phase HPLC columns. The Atlantis dC18 Column offers improved pH stability in addition to being compatible with water mobile phases.
The Atlantis dC18 Column is the perfect piece of lab equipment for reversed-phase HPLC because it is made of silica-based, difunctionally bonded C18 materials. The lab equipment has been constructed using optimized stationary phase physical properties such as end-capping, silica pore size, bonded phase ligand density, and ligand type to provide superior peak shape, low pH stability, resistance to dewetting (hydrophobic collapse), and improved polar compound retention. The Atlantis dC18 Column is one of the most dependable reversed-phase HPLC columns and may be used for both reversed-phase standard applications as well as the separation of polar chemicals.
Special packing material for the Atlantis dC18 column was created following significant study to deliver retention and separation of polar, water-soluble chemicals. The Atlantis dC18 Column delivers superb peak shapes for bases and is fully end-capped. Additionally, it ensures low pH stability as well as a prolonged column lifetime. Difunctional silane bonding chemistry, which provides good stability under acidic mobile circumstances, is used to achieve this.
We recommend that you store your analytes in the LCMS Certified Clear Glass 12 x 32 mm Screw Neck Vial, with Cap and Preslit PTFE/Silicone Septum, 2 mL Volume, 100/pk.
What Is The pH Range Offered By The Atlantis dC18 Column?
This particular Waters Atlantis dC18 Column offers analysis within the 3-7 pH range.
What Is The Maximum Pressure That The Atlantis dC18 Column Can Sustain?
The Atlantis dC18 Column listed here is able to work well with a maximum pressure of up to 6000 psi (415 Bar).