Chemistry |
C18 |
Separation Mode |
Reversed Phase |
Particle Substrate |
Silica |
pH Range Min |
2 pH |
pH Range Max |
8 pH |
Maximum Pressure |
6000 psi (415 Bar) |
Endcapped |
Yes |
Silanol Activity |
Low |
Particle Shape |
Spherical |
Particle Size |
5 µm |
Endfitting Type |
Waters |
Pore Size |
100 Å |
Format |
Column |
Surface Area |
340 |
System |
HPLC |
USP Classification |
L1 |
Inner Diameter |
4.6 mm |
Length |
100 mm |
Carbon Load |
16 % |
UNSPSC |
41115709 |
Brand |
SunFire |
Product Type |
Columns |
Units per Package |
1 pk |
SunFire C18 Column, 100Å, 5 µm, 4.6 mm X 100 mm, 1/pk
The SunFire C18 Column assists in providing general-purpose method development at low pH. The C18 ligand within the SunFire C18 Column is highly retentive, especially for basic compounds, making the lab equipment well suited for purification and impurity profile assays. With the SunFire C18 Column, you get the best in particle and bonding expertise to achieve the highest industry-level chromatographic performance.
The SunFire C18 Column offers excellent resolution, speed, and low backpressure. It also comes equipped with additional features such as excellent sensitivity, high peak capacity, and ultra-low bleed, which provide you with sharp peaks. You can use the SunFire C18 Column across a wide range of mass spectrometry applications with ease; the unique attributes of this column make the SunFire C18 Column crucial for any lab.
In contrast to most traditional silica-based HPLC columns, the SunFire C18 Column’s superior low pH stability enhances column lifetime. Additionally, by adding the analytical column to your lab, you get dependable equipment that is highly efficient and offers greater sensitivity. These features are achieved through the proprietary, state-of-the-art silica synthesis, bonding, end-capping, and packing technologies used in the manufacturing of the SunFire C18 Column. The sorbent used within the SunFire C18 Column, in combination with the new bonding and end-capping technologies, delivers superior peak shape performance. The lab equipment helps achieve symmetrical peaks for improved resolution and quantitation of acidic, neutral, and basic compounds at low and intermediate pH ranges.
You browse through the Waters brochure or visit our website to shop for lab equipment as per your needs. The website also enables you to connect with our global client support staff to whom you can direct any queries and concerns.
You might also be interested in reviewing the SunFire C18 VanGuard Cartridge, 100Å, 3.5 µm, 2.1 mm X 5 mm, 3/pk; the SunFire C18 VanGuard Cartridges are used to extend analytical column lifetime and performance by removing particulate contamination from the mobile phase stream. This cartridge is optimized to protect all 2.1 mm and 3.0 mm ID SunFire C18 analytical columns containing 3.5 µm sorbent particles.
What Does The Principle Of Mass Spectrometry Mean?
The principle of mass spectrometry (MS) is to generate ions from either inorganic or organic compounds by any suitable method, as well as to separate these ions by their mass to charge ratio (m/z) and to detect them qualitatively and quantitatively by their respective m/z and abundance.