Chemistry |
C18 |
Separation Mode |
Reversed Phase |
Particle Substrate |
Hybrid |
pH Range Min |
2 pH |
pH Range Max |
11 pH |
Maximum Pressure |
18000 psi (1240 Bar) |
Endcapped |
Yes |
Bonding Technology |
Shield RP18 |
Silanol Activity |
Low |
Particle Shape |
Spherical |
Particle Size |
1.7 µm |
Endfitting Type |
Parker-style |
Pore Size |
130 Å |
Format |
Column |
Surface Area |
185 |
System |
UHPLC, UPLC |
Particle Technology |
BEH |
USP Classification |
L1 |
Inner Diameter |
1 mm |
Length |
100 mm |
Carbon Load |
17 % |
eCord |
Yes |
UNSPSC |
41115709 |
Brand |
ACQUITY UPLC |
Product Type |
Columns |
Units per Package |
1 pk |
ACQUITY UPLC BEH Shield RP18 Column, 130Å, 1.7 µm, 1 mm X 100 mm, 1/pk
Use the ACQUITY UPLC BEH Column's peak shape improvement and high-resolution power for basic chemicals to achieve great results since the lab equipment has a unique chemistry that gives similar selectivity to a C18 column. This performance is achieved while the analytical column is compatible with 100% aqueous mobile phases. The embedded-polar group in the ACQUITY UPLC BEH Shield RP18 Column combines the hydrophobicity of a straight-chain alkyl ligand (C18) with the hydrophilicity of an embedded polar group (carbamate), providing it a distinct advantage in delivering outstanding results, particularly for phenolic chemicals. In addition to this, the ACQUITY BEH Shield RP18 Column is a required and strong tool for HPLC method development, complementing the ACQUITY BEH C18 and C8 phases.
Take advantage of the ACQUITY UPLC BEH Shield RP18 Column's unique location, which incorporates an embedded carbamate within the bonded phase ligand, combining elements of Waters' patented Shield Technology and BEH technology. The integrated polar group ligand provides alternative selectivity and an exceptional peak shape in this combination. Additionally, you will be able to operate with a wide pH range and the 1.7 µm BEH particle's ultra-efficiency. The ACQUITY UPLC BEH Shield RP18 Column is the perfect lab equipment because of these features.
Visit our website to discover more about the ACQUITY brand's whole product line. The website provides details on the items and accessories that work with them, as well as the technology that enables them. You can also order lab equipment straight from us through the website.
We recommend that you also invest in the ACQUITY UPLC BEH Shield RP18 VanGuard Pre-column, 130Å, 1.7 µm, 2.1 mm X 5 mm, 3/pk. The VanGuard Pre-column is an excellent piece of equipment for extending the life of your analytical column. Because the VanGuard Pre-column removes all chemical and particle pollutants from the mobile phase, the analytical column is protected. This ensures that your analysis is always accurate, exact, and trustworthy.
What Is The pH Limit For The ACQUITY UPLC BEH Shield RP18 Column?
The ACQUITY UPLC BEH Shield RP18 Column listed here offers a wide working range of 2-11 pH.
What Is The Maximum Pressure That The ACQUITY UPLC BEH Shield RP18 Column Can Take?
This particular ACQUITY UPLC BEH Shield RP18 Column is able to withstand up to 18000 psi (1240 Bar) pressure.