XBridge BEH C18 Column, 130Å, 3.5 µm, 3 mm X 50 mm, 1/pk

XBridge BEH C18 Column | 186003026


Streamline Purchasing with Customized Quotes

Streamline Purchasing with Customized Quotes

Shop on Waters.com and add items to your cart

Navigate to the Shopping Cart

Select Request a Quote to get your quote instantly


Product Description

As a workhorse for HPLC method development, XBridge BEH C18 sorbent can be used over an entire range of mobile phase pH (1-12). The trifunctionally bonded C18 ligand provides you with a universal column for most HPLC separations and gives you the widest usable pH range, superior low pH stability, and ultra-low column bleed.

Specifications

  • Chemistry

    C18

  • Separation Mode

    Reversed Phase

  • Particle Substrate

    Hybrid

  • pH Range Min

    1 pH

  • pH Range Max

    12 pH

  • Maximum Pressure

    6000 psi (415 Bar)

  • Endcapped

    Yes

  • Silanol Activity

    Low

  • Particle Shape

    Spherical

  • Particle Size

    3.5 µm

  • Endfitting Type

    Waters

  • Pore Size

    130 Å

  • Format

    Column

  • Surface Area

    185

  • System

    HPLC

  • Particle Technology

    BEH

  • USP Classification

    L1

  • Inner Diameter

    3 mm

  • Length

    50 mm

  • Carbon Load

    18 %

  • UNSPSC

    41115709

  • Brand

    XBridge

  • Product Type

    Columns

  • Units per Package

    1 pk

Product Support

Documents

Documents



What do you want to do?

What do you want to do?

Related Products

Back To Top Back To Top

XBridge BEH C18 Column, 130Å, 3.5 µm, 3 mm X 50 mm, 1/pk

Get reliable performance each time using the XBridge BEH C18 Column, as the lab equipment has been designed keeping in mind that column performance is crucial for method reliability. To ensure reliability, the manufacturing of the XBridge BEH C18 Column is carefully monitored and every step tightly controlled to maintain product reproducibility. Tests are also conducted every step of the way starting from raw material characterization to final batch analysis. This due diligence results in reliable results in every batch and column, no matter how many times you perform analysis.

The XBridge BEH C18 Column also enables you to maximize your productivity. The column design gives special consideration to versatility as selecting the most suitable column and separation conditions can be extremely difficult. The XBridge BEH C18 Column makes it easier for you to make this choice. This means that whether you need to develop a cutting-edge LC/MS assay or create a quality control method, the XBridge BEH C18 Column will enable you to do this while providing improved pH stability (1-12). Additionally, using the XBridge BEH C18 Column, you can be certain of increased column lifetime and enhanced column reliability while leveraging assay ruggedness.

The use of the XBridge BEH C18 Column enables you to eliminate the compromise on the sorbent selection. You can continue to leverage the flexibility of the column to work under any mobile phase, temperature, and pH conditions necessary to achieve the desired separation. The column also offers a wide range of pH.

You can quickly define conditions for rugged method development using the robust XBridge BEH C18 Column. These optimized approaches save you time, effort, and expense. These systematic changes over a wide range of mobile-phase pH give you the most control over analyte retention and selectivity.

Find more about our XBridge brand, by going through the available literature on our website that explains the technology and research that goes into the development. You can also find out how to reach out to our staff with any queries and also to shop for lab equipment directly from us through our website.

You may also be interested in the XBridge BEH C18 VanGuard Cartridge, 130Å, 3.5 µm, 2.1 mm X 5 mm, 3/pk.

What Pressure Can The XBridge BEH C18 Column Tolerate?

The recommended pressure range for XBridge BEH C18 Column is 4,000-5,000 psi even though it can tolerate pressures of up to 6,000 psi.