Chemistry |
C18 |
Separation Mode |
Reversed Phase |
Particle Substrate |
Hybrid |
pH Range Min |
1 pH |
pH Range Max |
12 pH |
Maximum Pressure |
6000 psi (415 Bar) |
Endcapped |
Yes |
Silanol Activity |
Low |
Particle Shape |
Spherical |
Particle Size |
5 µm |
Endfitting Type |
Waters |
Pore Size |
130 Å |
Format |
Column |
Surface Area |
185 |
System |
HPLC |
Particle Technology |
BEH |
USP Classification |
L1 |
Inner Diameter |
2.1 mm |
Length |
150 mm |
Carbon Load |
18 % |
UNSPSC |
41115709 |
Brand |
XBridge |
Product Type |
Columns |
Units per Package |
1 pk |
XBridge BEH C18 Column, 130Å, 5 µm, 2.1 mm X 150 mm, 1/pk
The XBridge BEH C18 Column, which delivers superior separation performance, resilience, and throughput for HPLC tests, makes it simple to transfer techniques from HPLC to UPLC and from UPLC to HPLC. The XBridge BEH C18 Column is the most well-suited lab equipment to address the most demanding chromatographic tasks, as it is designed to tolerate higher pressures. It also provides improved pH stability across a wide pH range while maintaining high efficiency. In addition, you'll benefit from unrivaled column longevity and the ability to deal with a wide range of mobile phase pH and temperatures.
The XBridge BEH C18 Column can help you increase your productivity. The XBridge BEH C18 Column will be appropriate lab equipment for creating a quality control method or developing a cutting-edge LC/MS assay, whether the goal is to establish a quality control method or a cutting-edge LC/MS assay. Furthermore, the analytical columns provide outstanding peak shape and peak capacity by increasing particle efficiency. Learn more about the complete range of XBridge columns available with us in various chemistries and configurations through our online store, where you can also purchase lab equipment directly from here.
You can rely on the XBridge BEH C18 Column to guarantee one of the most important aspects of method reliability: consistent column performance. You may expect the same performance from the XBridge BEH C18 Column throughout the rest of its life as it did on the first day.
The XBridge BEH C18 Column has relatively little retention loss or peak shape deterioration as compared to conventional columns. This is accomplished by the use of packing that employs proprietary bonding and end-capping methods, resulting in ligand stability and chromatographic repeatability at low pH. As a result, the XBridge BEH C18 Column has a long column lifetime without sterically obstructing the stationary phase.
You may be interested in exploring the XBridge BEH C18 VanGuard Cartridge, 130Å, 5 µm, 2.1 mm X 5 mm, 3/pk, which works in conjunction with the XBridge BEH C18 Column to deliver superior performance. It works by removing any particulate or chemical contaminants from entering the mobile phase, thus enhancing the performance of the column and also extending its lifetime.
What Is The pH Limit For The XBridge BEH C18 Column?
The XBridge BEH C18 Column listed here offers a very broad pH range of 1-12 pH.