Chemistry |
C18 |
Separation Mode |
Reversed Phase |
Particle Substrate |
Hybrid |
pH Range Min |
1 pH |
pH Range Max |
12 pH |
Endcapped |
Yes |
Silanol Activity |
Low |
Molecular Weight Range Min |
1000 |
Molecular Weight Range Max |
15000 |
Particle Shape |
Spherical |
Particle Size |
1.7 µm |
Endfitting Type |
Parker-style |
Pore Size |
130 Å |
QC Tested |
Peptide |
Format |
Column |
Surface Area |
185 |
System |
UHPLC, UPLC |
Particle Technology |
BEH |
USP Classification |
L1 |
Inner Diameter |
2.1 mm |
Length |
100 mm |
Carbon Load |
18 % |
UNSPSC |
41115709 |
Application |
Peptide |
Brand |
ACQUITY UPLC |
Product Type |
Columns |
Units per Package |
1 pk |
ACQUITY UPLC Peptide BEH C18 Column, 130Å, 1.7 µm, 2.1 mm X 100 mm, 1K - 15K, 1/pk
Successfully separate a wide range of peptides using the ACQUITY UPLC Peptide BEH C18 Column. The column is ideally suited for protein analysis as it is designed using Waters BEH particle and C18 bonding technologies so you get stable and reproducible peptide separations.
ACQUITY UPLC Peptide BEH C18 Column utilizes Peptide Separation Technology (PST) that has been formulated to help you meet the demanding requirements of peptide separations. This unique column chemistry combined with the benefits of sub-2 µm particles offers the ultimate resolution and can be used across a wide range of applications from high sensitivity proteomics to high mass load purification.
Depend on the ACQUITY UPLC Peptide BEH C18 Column for improved chromatography of peptides as it offers a range of unique benefits for peptide analysis. These include narrow, symmetrical peaks for best resolution, good peak shape, and retention in formic acid and trifluoroacetic acid (TFA) for optimal chromatography and detection. You also get successful separation of a wide range of peptides such as large and small, acidic and basic, hydrophobic and hydrophilic. The particle structure and bonding chemistry of the ACQUITY UPLC Peptide BEH C18 Column make it stable at pH 1 to 12 and at elevated temperatures as well. These unique attributes make the ACQUITY UPLC Peptide BEH C18 Column crucial lab equipment.
Use our catalog to get information regarding contacting our various offices and to shop for lab equipment. You can also learn more about various product offerings and what pieces of lab equipment are consistently used in conjunction with this product and more.
You may also be interested in the ACQUITY UPLC BEH C18 VanGuard Pre-column, 130Å, 1.7 µm, 2.1 mm X 5 mm, 3/pk. You can use the VanGuard Pre-column to enhance the life of your ACQUITY UPLC Peptide BEH C18 Column. The VanGuard Pre-column protects your analytical columns and other related products by removing all contaminants to optimize results.
What Factors Can Cause High Back Pressure And Split Peaks?
High backpressure and split peaks are not caused by a faulty column alone. Other factors to check include Mobile Phase(s), bacteria, precipitation, sample quality, and injection solvent strength.