SKU: 186003569
XBridge Peptide BEH C18 Column, 130Å, 3.5 µm, 4.6 mm X 150 mm, 1K - 15K, 1/pk

XBridge Peptide BEH C18 Columns | 186003569


Streamline Purchasing with Customized Quotes

Streamline Purchasing with Customized Quotes

Shop on Waters.com and add items to your cart

Navigate to the Shopping Cart

Select Request a Quote to get your quote instantly


Product Description

The XBridge BEH130 C18 Peptide Separation Technology (PST) columns are optimized and QC tested for peptide separations. The small-pore (130Å) trifunctionally bonded BEH particle offers you the widest usable pH range, superior low pH stability, and ultra-low column bleed to assay samples for proteomics, protein characterization, and peptide synthesis.

Specifications

  • Chemistry

    C18

  • Separation Mode

    Reversed Phase

  • Particle Substrate

    Hybrid

  • pH Range Min

    1 pH

  • pH Range Max

    12 pH

  • Maximum Pressure

    6000 psi (415 Bar)

  • Endcapped

    Yes

  • Silanol Activity

    Low

  • Molecular Weight Range Min

    1000

  • Molecular Weight Range Max

    15000

  • Particle Shape

    Spherical

  • Particle Size

    3.5 µm

  • Endfitting Type

    Waters

  • Pore Size

    130 Å

  • QC Tested

    Peptide

  • Format

    Column

  • Surface Area

    185

  • System

    HPLC

  • Particle Technology

    BEH

  • USP Classification

    L1

  • Inner Diameter

    4.6 mm

  • Length

    150 mm

  • Carbon Load

    17 %

  • UNSPSC

    41115709

  • Application

    Peptide

  • Brand

    XBridge

  • Product Type

    Columns

  • Units per Package

    1 pk

Product Support

Documents

Documents



What do you want to do?

What do you want to do?
Back To Top Back To Top

XBridge Peptide BEH C18 Column, 130Å, 3.5 µm, 4.6 mm X 150 mm, 1K - 15K, 1/pk

Add the XBridge Peptide BEH C18 Column to your lab equipment collection as the small-pore (130Å) trifunctionally bonded BEH particle offers you the widest usable pH range, superior low pH stability, and ultra-low column bleed to assay samples for proteomics, protein characterization, and peptide synthesis. The column is optimized using Waters Peptide Separation Technology (PST) and is QC tested for peptide separations. The synthetic particles offer the highest quality combined with consistent performance.

You can depend on the reliability of the analytical column and get consistent batch-to-batch synthetic peptide and protein digest separations. To make certain the stability of peptide separation methods, the XBridge Peptide BEH C18 Column is QC tested with a peptide map. This is made possible using well-characterized, state-of-the-art bonding procedures for the C18 ligand. It delivers predictable behavior with the variety of samples that are used in proteomics, protein characterization, and peptide synthesis. The XBridge Peptide BEH C18 Column is made using techniques that ensure stable particle structure and bonding chemistry from pH 1 to 12 and at elevated temperatures.

The XBridge Peptide BEH C18 Column uses packing materials that have been designed to provide excellent peak shape, high efficiency, and excellent stability, and they are manufactured in a cGMP, ISO 9002 certified plant using ultra-pure reagents. In addition to this, each batch of XBridge Peptide BEH C18 Column material is qualified with a peptide separation, and the results are held to narrow specification ranges. This is done to make sure excellent, reproducible performance for peptide separations.

Every column is tested and a Performance Test Chromatogram, along with a Certification of Acceptance, is included in the packaging with each column.

The XBridge Peptide BEH C18 Column is available in other variations that can be found via our website, where you can also shop for lab equipment. You can also reach out to our offices worldwide and contact members of our staff should you have any queries regarding the products or the technology. We also recommend the use of the XBridge BEH C18 VanGuard Cartridge, 130Å, 3.5 µm, 3.9 mm X 5 mm, 3/pk with your column to enhance its lifetime and performance.

What Pressure Can The XBridge Peptide BEH C18 Column Tolerate?

The XBridge Peptide BEH C18 Column can tolerate pressures of up to 6000 psi (400 Bar or 40 Mpa). Although, it is recommended that a pressure range between 4000-5000 psi be used as higher pressures can reduce the column’s performance and lifetime.