Chemistry |
C18 |
Separation Mode |
Reversed Phase |
Particle Substrate |
Hybrid |
pH Range Min |
1 pH |
pH Range Max |
12 pH |
Maximum Pressure |
6000 psi (415 Bar) |
Endcapped |
Yes |
Silanol Activity |
Low |
Particle Shape |
Spherical |
Particle Size |
3.5 µm |
Endfitting Type |
Waters |
Pore Size |
130 Å |
Format |
Method Validation Kit |
Surface Area |
185 |
System |
HPLC |
Particle Technology |
BEH |
USP Classification |
L1 |
Inner Diameter |
4.6 mm |
Length |
150 mm |
Carbon Load |
18 % |
UNSPSC |
41115709 |
Brand |
XBridge |
Product Type |
Column Kits |
Units per Package |
3 pk |
XBridge BEH C18 Method Validation Kit, 130Å, 3.5 µm, 4.6 mm X 150 mm, 3/pk
Choose an LC lab equipment whose capabilities can meet existing and future demands of the challenging chromatographic environment.
Designed to be usable across a range of applications and various HPLC method developments, the sorbent of the XBridge BEH C18 Method Validation Kit makes it possible to be used over an entire range of mobile phase pH (1-12). Its trifunctionally bonded C18 ligand equips you with a universal column for most HPLC separations and gives you the widest usable pH range, superior low pH stability, and ultra-low column bleed.
The XBridge BEH C18 Method Validation Kit has been developed with the goal of maximizing your productivity, whether you aim to develop a leading-edge LC/MS assay or to create a quality control method. The analytical column enables you to achieve this by offering improved pH stability which results in increased column lifetime. It also provides assay ruggedness through enhanced column reliability. Its ability to maximize particle efficiency gives you unmatched peak shape and peak capacity.
As reproducible column performance is one of the most critical factors for method reliability, we take special care in the manufacturing of all lab equipment. Each step of our column manufacturing process is tightly controlled to maintain unmatched product reproducibility. Tests are performed at every level from raw material characterization to final batch analysis to make sure that the XBridge BEH C18 Method Validation Kit you use today will perform the same from column-to-column, batch-to-batch, and year-to-year.
To see more variations of the product listed here as well as related products and to shop for lab equipment, you can use our catalog.
You may also be interested in XBridge BEH C18 VanGuard Cartridge, 130Å, 3.5 µm, 3.9 mm X 5 mm, 3/pk. Use the VanGuard Cartridge to prolong the life of the XBridge BEH C18 Method Validation Kit, being certain that the analytical column will continue to perform at its optimum. This is made sure as the VanGuard Cartridge removes all particulate and chemical contaminations from the mobile phase stream, resulting in reliable results each time.
Do I Need An Autosampler?
The use of autosamplers is recommended as autosamplers and robotic workstations provide reproducible injections and allow automation of the chromatographic separation.