XBridge BEH Shield RP18 Method Validation Kit, 130Å, 5 µm, 4.6 mm X 150 mm, 3/pk

XBridge BEH Shield RP18 Method Validation Kit | 186003797


Streamline Purchasing with Customized Quotes

Streamline Purchasing with Customized Quotes

Shop on Waters.com and add items to your cart

Navigate to the Shopping Cart

Select Request a Quote to get your quote instantly


Product Description

XBridge BEH Shield RP18 columns complement the XBridge BEH C18 and C8 phases and provide a necessary and powerful tool for HPLC method development. The embedded carbamate group in the bonded phase ligand provides alternate selectivity, especially for phenolic compounds compared to straight chain alkyl columns.

Specifications

  • Chemistry

    C18

  • Separation Mode

    Reversed Phase

  • Particle Substrate

    Hybrid

  • pH Range Min

    2 pH

  • pH Range Max

    11 pH

  • Maximum Pressure

    6000 psi (415 Bar)

  • Endcapped

    Yes

  • Bonding Technology

    Shield RP18

  • Silanol Activity

    Low

  • Particle Shape

    Spherical

  • Particle Size

    5 µm

  • Endfitting Type

    Waters

  • Pore Size

    130 Å

  • Format

    Method Validation Kit

  • Surface Area

    185

  • System

    HPLC

  • Particle Technology

    BEH

  • USP Classification

    L1

  • Inner Diameter

    4.6 mm

  • Length

    150 mm

  • Carbon Load

    17 %

  • UNSPSC

    41115709

  • Brand

    XBridge

  • Product Type

    Column Kits

  • Units per Package

    3 pk

Product Support

Documents

Documents



What do you want to do?

What do you want to do?

Related Products

Back To Top Back To Top

XBridge BEH Shield RP18 Method Validation Kit, 130Å, 5 µm, 4.6 mm X 150 mm, 3/pk

The XBridge BEH Shield RP18 Columns make it simple to conduct superior base separation. There is a decrease in silanol interactions with basic analytes when using the XBridge BEH Shield RP18 Method Validation Kit. The lab equipment uses the proprietary Shield Technology to produce extremely symmetrical, efficient peaks with better peak shape. This is made possible by the "Shielding" effect, which is the deactivation of basic analytes. The XBridge BEH Shield RP18 Method Validation Kit performs better than conventional C18 columns, which have poor peak symmetry because of secondary interactions with basic chemicals caused by weak cation exchange with lingering surface silanols.

Enhance the essential test conditions required for a successful separation using the XBridge BEH Shield RP18 Method Validation Kit. With this lab equipment, you may successfully operate over a wide pH range with a variety of solvents since the XBridge BEH Shield RP18 Method Validation Kit gives an alternate selectivity.

The analytical column is the gold standard for LC method toughness and lifespan because it offers greater pH stability over the widest pH range, along with excellent efficiency and symmetrical peak form. Utilize pH's strength and the lab's equipment's adaptability with confidence to create solid separations.

You can be sure that when you buy from Waters, you will get only the best lab equipment to satisfy your needs for analysis. This is because we maintain unequaled product repeatability by meticulously monitoring and tightly controlling every stage of our manufacturing process. From raw material characterization through final batch analysis, testing is a part of this process. You have the assurance that the XBridge BEH Shield RP18 Method Validation Kit will give the same performance year after year, thanks to this strict respect for standards.

Filter out any unwanted pollutants from the XBridge Column using the XBridge BEH Shield RP18 VanGuard Cartridge, 130Å, 5 µm, 3.9 mm X 5 mm, 3/pk.

What Is The pH Range Across Which The XBridge BEH Shield RP18 Method Validation Kit Operates?

The XBridge BEH Shield RP18 Method Validation Kit listed here offers a broad operational pH range of 2-11 pH.

What Is The Maximum Pressure That The XBridge BEH Shield RP18 Method Validation Kit Can Sustain?

This particular XBridge BEH Shield RP18 Method Validation Kit can tolerate a maximum pressure of up to 6000 psi (415 Bar).