SKU: 186004476
Isolator Column



Isolator Columns | 186004476


Streamline Purchasing with Customized Quotes

Streamline Purchasing with Customized Quotes

Shop on Waters.com and add items to your cart

Navigate to the Shopping Cart

Select Request a Quote to get your quote instantly


Product Description

Designed to be used with Waters ACQUITY Application Specific Kits, the Isolator Column separates background contaminates from the sample to be analyzed, thus removing interferences and allowing for extremely low detection limits. Utilized for such applications as Perfluorinated Compounds (PFCs/PFOA/PFOS) and Bisphenol A the Isolator column features the same technological advances as the other columns in the ACQUITY UPLC product family and is designed, tested and certified to operate with ACQUITY UPLC Systems.

Specifications

  • Separation Mode

    Reversed Phase

  • Particle Substrate

    Hybrid

  • pH Range Min

    1 pH

  • pH Range Max

    12 pH

  • Endcapped

    Yes

  • Silanol Activity

    Low

  • Particle Shape

    Spherical

  • Endfitting Type

    Parker-style

  • Format

    Column

  • System

    UHPLC, UPLC

  • Inner Diameter

    2.1 mm

  • Length

    50 mm

  • UNSPSC

    41115709

  • Brand

    ACQUITY UPLC

  • Product Type

    Columns

  • Units per Package

    1 pk

Product Support

Documents

Documents

No Results Found


Isolator Column

Use the Isolator Column to isolate and separate samples that need to be analyzed from background contaminants, thus removing interference and allowing for extremely low detection limits. The lab equipment has been specially designed to be used with Waters ACQUITY Application Specific Kits. Application of the Isolator Column are wide and include Perfluorinated Compounds (PFCs/PFOA/PFOS) and Bisphenol-A. Some key cutting-edge technological advances that are utilized in other columns in the ACQUITY UPLC product family are also featured in the Isolator Column. You can be certain of the compatibility of the column with the ACQUITY UPLC Systems as it has been designed, tested, and certified to operate with ACQUITY UPLC Systems.

The Isolator Column is in the flow path between the mixer of the binary solvent manager and the injector of the sample manager. During analysis, the isolator column retains the background perfluorinated compounds, separating them from analytes of interest. The increased retention time of the background compounds makes them easily distinguishable by mass analysis.

To explore the complete range of Isolator columns and other similar products, or to find more products that are compatible and add them to your analytical arsenal, we recommend that you shop for lab equipment from our website and catalog. You will also come across several reference materials that will help you make informed choices by learning more about our technology and development.

You may also be interested in the BPA Method Kit which is Waters ACQUITY UPLC solution for the analysis of Bisphenol A in Drinking Water and is fully compliant with ASTM Method D7574-09. Optimized for use with the ACQUITY system, the selection of these products has been done to make sure you get the highest performance available. This kit contains ACQUITY BEH C18, 1.7um, 2.1 x 50mm Column; ACQUITY Isolator Column; Oasis HLB 5cc (200mg) LP Glass Cartridges and LCMS Certified Vials.

Why Are PFCs Studied And Hard To Detect?

Perfluorinated compounds (PFCs) are strongly associated with a variety of human disorders, including cancer, which makes it important to monitor the level of PFCs in consumables like drinking water. However, as this class of molecules is particularly chemically inert and resistant to degradation, it is particularly hard to isolate and detect.