Chemistry |
Amide |
Separation Mode |
Hydrophilic Interaction (HILIC) |
Particle Substrate |
Hybrid |
pH Range Min |
2 pH |
pH Range Max |
11 pH |
Maximum Pressure |
18000 psi (1240 Bar) |
Endcapped |
No |
Silanol Activity |
Low |
Particle Shape |
Spherical |
Particle Size |
1.7 µm |
Endfitting Type |
Parker-style |
Pore Size |
130 Å |
Format |
Column |
Surface Area |
185 |
System |
UHPLC, UPLC |
Particle Technology |
BEH |
USP Classification |
L68 |
Inner Diameter |
1 mm |
Length |
100 mm |
Carbon Load |
12 % |
eCord |
Yes |
UNSPSC |
41115709 |
Brand |
ACQUITY UPLC |
Product Type |
Columns |
Units per Package |
1 pk |
ACQUITY UPLC BEH Amide Column, 130Å, 1.7 µm, 1 mm X 100 mm, 1/pk
To retain extremely polar compounds, you need a UPLC column that’s more than up to the task. That’s why we’re proud to offer the ACQUITY UPLC BEH Amide Column, the perfect HILIC separation tool that harnesses the power and performance of UPLC technology. With a very small particle size and rugged column format, the ACQUITY UPLC BEH Amide Column is ready to take on your difficult separations with ease. What’s more, this amide column is also a great candidate to be used for carbohydrate and sugar analysis. Add the ACQUITY UPLC BEH Amide Column to your lab’s toolkit and get back to the assays that matter today.
At the core of the ACQUITY UPLC BEH Amide Column is the Ethylene-Bridged Hybrid base particle. This particle utilizes a trifunctionally-bonded amide, enabling HILIC separations that weren’t possible without this new technology. What’s more, with the ruggedness this particle provides at extreme pH conditions, it’s easy to see why scientists across the globe are using ACQUITY BEH Columns for their separations.
Column protection against particulate contaminants is one of the biggest obstacles you’ll encounter when developing HILIC separations. That’s why at Waters, we’re happy to provide a column protection solution to make that obstacle much easier to overcome. We’re proud to present VanGuard Pre-columns and guard cartridges to protect your analytical column from chemical fouling. Add the ACQUITY UPLC BEH Amide VanGuard Pre-column to your analytical workflow and your column will be protected from harmful contaminants. Plus, when the pre-column starts to wear and needs to be replaced, you can easily do so with another genuine replacement from Waters.
The ACQUITY UPLC BEH Amide Column is designed specifically to retain highly polar analytes that are too polar to be retained by reverse-phase techniques. That’s why this breakthrough UPLC column utilizes a HILIC separation mode. Compatibility with HILIC makes this column uniquely suited for sugar and carbohydrate analysis as well.
When you trust the team at Waters with your LC-MS needs, you can rest easy knowing your lab will be equipped with all the essentials and products that can help you change your workflows for the better. We have much more than just UPLC columns like the ACQUITY UPLC BEH Amide Column, so shop lab equipment to explore everything we have to offer.
How Small is the ACQUITY UPLC BEH Amide Column’s Inner Diameter?
The ACQUITY UPLC BEH Amide Column as an inner diameter of 1 mm.