Prep Guard Cartridge 19 mm x 10 mm

SKU: 186005418
XSelect CSH C18 Prep Guard Cartridge, 130Å, 5 µm, 19 mm X 10 mm, 1/pk

XSelect CSH C18 Prep Guard Cartridge | 186005418


Streamline Purchasing with Customized Quotes

Streamline Purchasing with Customized Quotes

Shop on Waters.com and add items to your cart

Navigate to the Shopping Cart

Select Request a Quote to get your quote instantly


Product Description

XSelect CSH C18 columns can be used as general purpose columns that provide alternative selectivity compared to other C18 sorbents. Charged Surface Hybrid (CSH) technology helps you overcome column related problems such as peak shape asymmetry and poor loading for basic compounds, column bleed, and slow mobile-phase re-equilibration.

Specifications

  • Chemistry

    C18

  • Separation Mode

    Reversed Phase

  • Particle Substrate

    Hybrid

  • pH Range Min

    1 pH

  • pH Range Max

    11 pH

  • Temperature Limits

    80 C (Low pH) / 45 C (High pH)

  • Maximum Pressure

    6000 psi (415 Bar)

  • Endcapped

    Yes

  • Silanol Activity

    Low

  • Particle Shape

    Spherical

  • Particle Size

    5 µm

  • Pore Size

    130 Å

  • Format

    Prep Guard Cartridge

  • Surface Area

    185

  • System

    HPLC Preparative

  • Particle Technology

    CSH

  • Technique

    LC, LC/MS

  • USP Classification

    L1

  • Inner Diameter

    19 mm

  • Length

    10 mm

  • Carbon Load

    15 %

  • UNSPSC

    41115709

  • Brand

    XSelect

  • Product Type

    Guards

  • Units per Package

    1 pk

Product Support

Documents

Documents



What do you want to do?

What do you want to do?

Related Products

Back To Top Back To Top

XSelect CSH C18 Prep Guard Cartridge, 130Å, 5 µm, 19 mm X 10 mm, 1/pk

The Waters XSelect CSH C18 equipment collection includes Analytical Columns, Prep Columns and Guard Cartridges. These are typically used as general-purpose columns to provide alternative unique selectivity in contrast with other C18 sorbents. The XSelect CSH C18 Prep Guard Cartridge is designed on the Charged Surface Hybrid (CSH) technology, which assists the column in overcoming challenges that regular columns generally face, namely, peak shape asymmetry and poor landing for basic compounds, column bleed, and slow mobile-phase re-equilibrium.

The XSelect CSH C18 collection of Columns, Prep Columns, and Guard Cartridges are designed to offer diverse analyte selectivity to separate closely eluting sample constituents. They will deliver unmatched selectivity and reproducibility for your chromatographic analysis. The XSelect CSH C18 Prep Guard Cartridge is made from the same packing material as the XSelect CSH C18 analytical Column, making it compatible with the analytical column and helps in protecting the column and extending its lifetime.

The application of the CSH technology-based Column will provide you with many advantages, including superior peak shape for basic compounds and high peak capacity for complex mixtures; increased mass load for preparative separation without having to use ion-pairing reagents; and rapid column equilibration. CSH technology enables you to quickly change mobile-phase conditions and pH to quickly screen multiple mobile-phase conditions. With its protective and time-saving features, the XSelect CSH C18 Prep Guard Cartridge will enable you to reduce purification and lab costs, making it a vital piece of equipment to have.

Browse our website to shop for lab equipment as per your laboratory needs. You might also be interested in reviewing the AutoPurification System Standard. The Quality Control Reference Material portfolio is a unique collection of standards and mixtures. These products allow the user to evaluate and benchmark their chromatography system before the analysis of critical material. The products in the portfolio are all specially formulated based on the expertise of Waters scientists. The AutoPurification Dye Standard contains 3 compounds, including Thionin, Thioflavin, and Crystal Violet. This standard mix is used to confirm the benchmark performance of a Preparative/Purification System through fraction collection. This particular QCRM is specially formulated to allow the user to verify correct fraction collection. This test is highly valuable to perform upon first use/installation and any time the system has not been used or has had any changes.

What Are The Recommended Pressure And Temperature You Can Use With The XSelect CSH C18 Prep Guard Cartridge?

The XSelect CSH C18 Column is designed to withstand a pressure of 6000 psi (or 415 Bar) along with a particle size of 10 µm and pore size of 130 Å. However, it is always recommended not to cross the maximum range to ensure the best possible column lifetime and effectiveness. The recommended temperature for your equipment is 80 C under Low pH conditions and 45 C in high pH conditions.