SKU: 186005593
ACQUITY UPLC Peptide BEH C18 Column, 300Å, 1.7 µm, 1 mm X 100 mm, 1K - 30K, 1/pk

ACQUITY UPLC Peptide BEH C18 Column | 186005593


Streamline Purchasing with Customized Quotes

Streamline Purchasing with Customized Quotes

Shop on Waters.com and add items to your cart

Navigate to the Shopping Cart

Select Request a Quote to get your quote instantly


Product Description

The ACQUITY BEH300 C18 Peptide Separation Technology (PST) columns have been specially optimized and QC tested for peptide separations. The wide-pore (300Å) trifunctionally bonded BEH particle offers the widest usable pH range, superior low pH stability, and ultra-low column bleed to assay samples for proteomics, protein characterization, and peptide synthesis.

Specifications

  • Chemistry

    C18

  • Separation Mode

    Reversed Phase

  • Particle Substrate

    Hybrid

  • pH Range Min

    1 pH

  • pH Range Max

    12 pH

  • Endcapped

    Yes

  • Silanol Activity

    Low

  • Molecular Weight Range Min

    1000

  • Molecular Weight Range Max

    30000

  • Particle Shape

    Spherical

  • Particle Size

    1.7 µm

  • Endfitting Type

    Parker-style

  • Pore Size

    300 Å

  • QC Tested

    Peptide

  • Format

    Column

  • System

    UHPLC, UPLC

  • Particle Technology

    BEH

  • USP Classification

    L1

  • Inner Diameter

    1 mm

  • Length

    100 mm

  • Carbon Load

    18 %

  • UNSPSC

    41115709

  • Application

    Peptide

  • Brand

    ACQUITY UPLC

  • Product Type

    Columns

  • Units per Package

    1 pk

Product Support

Documents

Documents



What do you want to do?

What do you want to do?

Related Products

Back To Top Back To Top

ACQUITY UPLC Peptide BEH C18 Column, 300Å, 1.7 µm, 1 mm X 100 mm, 1K - 30K, 1/pk

Utilize the ACQUITY UPLC Peptide BEH C18 Column to improve peptide chromatography. It will help you achieve compact, symmetrical peaks for the best resolution and successfully separate a variety of peptides, including hydrophobic and hydrophilic, big and small, acidic and basic. Formic acid and trifluoroacetic acid (TFA) provide good peak shapes and retention for effective chromatography and detection.

The Waters Peptide Separation Technology (PST), which uses BEH Technology particles, is the foundation for the ACQUITY UPLC Peptide columns, which are specially QC validated with a peptide map and meet the stringent requirements for the BEH Technology particles. The durability of well-developed peptide separations and predictable behavior with a variety of samples utilized in proteomics, protein characterization, and peptide synthesis is ensured by doing this. Sharp, symmetrical peaks are produced over a broad range of peptide characteristics and application requirements thanks to the surface chemistry.

The large pore (300 ) and tri-functional bonding of the Waters ACQUITY UPLC Peptide BEH C18 Columns make them special. These columns provide remarkable low pH stability and a broad, usable pH range (1–12). They provide extremely low column bleed to assay samples for proteomics, protein characterization, and peptide synthesis, making them essential pieces of lab equipment for any scientist.

The ACQUITY UPLC Peptide BEH C18 Columns are developed in a cGMP, ISO 9002 accredited plant using ultra-pure reagents and are specifically designed to work with ACQUITY UPLC and ACQUITY PREMIER systems. Each batch is qualified for peptide mapping after undergoing chromatographic testing with neutral, acidic, and basic analytes. The results are held to limited specification ranges to ensure reproducibility and consistency, batch over batch and column over column, so that you receive superb lab equipment that offers reliable analysis and reproducible performance.

If you are interested in reviewing additional product offerings from Waters, please review our catalog or check out our website, from where you can directly shop for lab equipment. You should also review the ACQUITY UPLC Peptide BEH C18 VanGuard Pre-column, 300Å, 1.7 µm, 2.1 mm X 5 mm, 1K - 30K, 3/pk; VanGuard pre-columns are the first guard column devices designed for routine use at pressures up to 15000 psi (1030 bar) in applications run on the ACQUITY UPLC System. This specific offering is specifically QC tested with a peptide map to help ensure consistent performance and increased analytical column life.

Should I Employ An Auto-Sampler?

Although autosamplers and robotic workstations enable automated chromatographic separation and offer reproducible injections, it is important to keep in mind that despite their benefits, they will also significantly increase the cost of your system.