Chemistry |
C18 |
Separation Mode |
Reversed Phase |
Particle Substrate |
Hybrid |
pH Range Min |
1 pH |
pH Range Max |
12 pH |
Maximum Pressure |
18000 psi (1240 Bar) |
Endcapped |
Yes |
Silanol Activity |
Low |
Particle Shape |
Spherical |
Particle Size |
1.7 µm |
Endfitting Type |
Parker-style |
Pore Size |
130 Å |
Format |
Column |
Surface Area |
185 |
System |
UHPLC, UPLC |
Particle Technology |
BEH |
USP Classification |
L1 |
Inner Diameter |
2.1 mm |
Length |
75 mm |
Carbon Load |
18 % |
eCord |
Yes |
UNSPSC |
41115709 |
Brand |
ACQUITY UPLC |
Product Type |
Columns |
Units per Package |
1 pk |
ACQUITY UPLC BEH C18 Column, 130Å, 1.7 µm, 2.1 mm X 75 mm, 1/pk
Achieve unprecedented levels of efficiency, peak symmetry, and chemical stability using the universal ACQUITY UPLC BEH C18 Column. The lab equipment is well suited to analyze a wide range of analytes. The analytical column is tri-functionally bonded and can be used as a universal method development tool. It offers the delivery of exceptionally low as well as high-pH stability for all analyte types. Using the ACQUITY UPLC BEH C18 Column, you can leverage the industry-leading mobile phase pH range (1-12) in addition to high-temperature stability (80 °C) to achieve outstanding analysis.
Use the ACQUITY UPLC BEH C18 Column to impact the retention, selectivity, and sensitivity of ionizable compounds. The packing materials used in the ACQUITY UPLC BEH C18 Column have been designed specifically for use with the ACQUITY UPLC System. Like all our lab equipment, the analytical column is manufactured in a cGMP, ISO 9001 certified plant using ultra-pure reagents. In addition to this, each batch of ACQUITY UPLC BEH C18 Column packing material is tested chromatographically with acidic, basic, and neutral analytes, and the results are held to tight scrutiny to make sure of the intended excellent, reproducible performance. Also included are a Performance Chromatogram and a Certificate of Batch Analysis the eCord™ Intelligent Chip after each column is individually tested, so you can be certain of its performance.
To find the complete range of our ACQUITY products, including analytical columns and their guards, browse through our website. The website will also guide you towards compatible products to be used in conjunction with the columns to complete your analytical range, as well as to shop for lab equipment.
You may also be interested in the Neutrals QC Reference Material which contains, one ampule with 10 μL/mL acetone, 0.25 mg/ mL naphthalene, and 0.4 mg/ mL acenaphthene in 50/50 acetonitrile/water, 2 mL. The Neutrals QC Reference Material is designed for use with any chromatographic systems containing a UV detector. It is intended to be used as a system benchmarking standard and contains only neutral compounds. The QC Reference Material will provide confidence in your results when used consistently. It also helps to reduce troubleshooting and re-run time and enables cross-laboratory result comparisons. In addition to this, the reference material is adaptable to a wide variety of separation methods.
What Pressure Can The ACQUITY UPLC BEH C18 Column Work With?
The ACQUITY UPLC BEH C18 Column can tolerate operating pressures up to 18000 psi (1241 bar or 124 MPa).