Chemistry |
PFP/Fluoro-Phenyl |
Separation Mode |
Reversed Phase |
Particle Substrate |
Silica |
pH Range Min |
2 pH |
pH Range Max |
8 pH |
Temperature Limits |
45 C |
Maximum Pressure |
18000 psi (1240 Bar) |
Endcapped |
No |
Bonding Technology |
PFP |
Silanol Activity |
High |
Particle Shape |
Spherical |
Particle Size |
1.8 µm |
Endfitting Type |
Parker-style |
Pore Size |
100 Å |
Format |
Column |
Surface Area |
230 |
System |
UHPLC, UPLC |
Particle Technology |
HSS |
USP Classification |
L43 |
Inner Diameter |
3 mm |
Length |
100 mm |
Carbon Load |
7 % |
eCord |
Yes |
UNSPSC |
41115709 |
Brand |
ACQUITY UPLC |
Product Type |
Columns |
Units per Package |
1 pk |
ACQUITY UPLC HSS PFP Column, 100Å, 1.8 µm, 3 mm X 100 mm, 1/pk
The trifunctionally bonded, non-end-capped ACQUITY UPLC HSS PFP pentafluorophenyl (PFP) chemical column is made of silica and is intended for low pH separations that call for alternate selectivity to a completely end-capped, high coverage C18 phase. The ACQUITY UPLC HSS PFP Column is the best lab equipment for polar analytes, halogenated chemicals, positional isomers, and planar aromatic compounds. This is due to the column's ability to combine a number of retention mechanisms, including hydrophobic, dipole-dipole, hydrogen-bonding, and aromatic (pi-pi) interactions.
For PFP stationary phases, the ACQUITY UPLC HSS PFP Column offers the best repeatability, peak form, and scalability in the market. The ACQUITY UPLC HSS PFP Column offers remarkable batch-to-batch repeatability as well as consistent selectivity throughout UPLC and HPLC particle sizes thanks to Waters' use of Quality Systems in the manufacturing of all lab equipment.
Utilize the superior peak form and retention of the ACQUITY UPLC HSS PFP Column for the separation of beta-blockers in comparison to conventional PFP core-shell columns. To ensure outstanding, repeatable performance, each batch of ACQUITY UPLC HSS PFP Column material is tested chromatographically with acidic, basic, and neutral analytes, and the results are held to limited specification ranges.
We recommend that you store your samples and analytes in the TruView LCMS Certified Clear Glass 12 x 32 mm Screw Neck Vial, with Cap and Preslit PTFE/Silicone Septum, 2 mL Volume, 100/pk. TruView LCMS Certified Glass Vials use a production procedure that minimizes adsorption. High recoveries of polar analytes are produced by this technique because the circumstances limit the concentration of free ions on the glass surface. Using a number of methods, including LC/UV and UPLC/MS, all vials are extensively evaluated for dimensional features, chemical purity, and adsorption. In this test, MS detection is used in an objective manner to check for any ionized masses independent of their source. The total ion count and the existence of clusters in the high mass range are the two criteria defined for tests that are done in scan mode.
What Is The pH Range Offered By The ACQUITY UPLC HSS PFP Column?
The ACQUITY UPLC HSS PFP Column listed here is able to deliver results within the 2-8 pH range.
What Are The Temperature Limits Of The ACQUITY UPLC HSS PFP Column?
The column is able to tolerate a maximum of 45 C.