Chemistry |
C18 |
Separation Mode |
Reversed Phase |
Particle Substrate |
Hybrid |
pH Range Min |
1 pH |
pH Range Max |
11 pH |
Maximum Pressure |
10000 psi (690 Bar) |
Endcapped |
Yes |
Silanol Activity |
Low |
Particle Shape |
Spherical |
Particle Size |
2.5 µm |
Endfitting Type |
Parker-style |
Pore Size |
130 Å |
Format |
Column |
Surface Area |
185 |
System |
UHPLC, UPLC |
Particle Technology |
CSH |
USP Classification |
L1 |
Inner Diameter |
4.6 mm |
Length |
100 mm |
Carbon Load |
15 % |
UNSPSC |
41115709 |
Brand |
XSelect |
Product Type |
Columns |
Units per Package |
1 pk |
XSelect CSH C18 XP Column, 130Å, 2.5 µm, 4.6 mm X 100 mm, 1/pk
Use the general-purpose Waters XSelect CSH C18 XP Column in your lab to benefit from alternative selectivity compared to other C18 sorbents. The use of the Charged Surface Hybrid (CSH) technology in the analytical equipment enables superior peak shape and increased loading capacity for basic compounds. The 2.5 µm eXtended Performance [XP] lab equipment comes packed in ultra-low dispersion hardware, which enables exceptional separation performance, robustness, and throughput for HPLC assays while enabling a seamless transition path toward UPLC adoption.
Using the XSelect CSH C18 Column, you can easily achieve unmatched selectivity and reproducibility for your chromatographic analysis. This is because the XSelect analytical column offers diverse analyte selectivity to separate closely eluting sample constituents.
To conduct higher resolution separations that are required for complex samples in order to isolate and quantify the samples, opt for the XSelect CSH C18 Column. The unique phases of the XSelect CSH C18 Column combine efficiency and selectivity to enhance the resolution of very complex samples. By using the lab equipment, you can also save time and effort when developing a chromatographic assay and give exceptional separation performance, robustness, and throughput for HPLC assays. The column makes it possible for you to perform these activities while being fully compatible with all HPLC, UPLC, and UHPLC technologies.
The XSelect CSH C18 Column offers outstanding performance and equivalent backpressure when it is compared to core-shell columns. Like other fully-porous particle columns, the XSelect CSH C18 Column also offers improved loading capacity and particle size scalability due to the use of Charged Surface Hybrid (CSH) technology. The CSH Technology improves all facets of liquid chromatography performance in acidic, low ionic strength mobile phases.
Shop for lab equipment directly from our website and use it to reach out to a member of our staff should you have any concerns or queries. We have offices in various locations globally.
Protect your analytical column using the XSelect CSH C18 XP VanGuard Cartridge, 130Å, 2.5 µm, 3.9 mm X 5 mm, 3/pk.
What Role Does Mobile Phase Perform In HPLC?
The mobile phase has been properly termed as the lifeline of the HPLC system. It plays the crucial role of transport of the sample through the separation column and subsequently to the detector for identification of the separated components.