Chemistry |
2-Ethylpyridine |
Separation Mode |
SuperCritical Fluid (SFC) |
Particle Substrate |
Hybrid |
Maximum Pressure |
6000 psi (415 Bar) |
Endcapped |
No |
Silanol Activity |
Medium |
Particle Shape |
Spherical |
Particle Size |
1.7 µm |
Endfitting Type |
Parker-style |
Pore Size |
130 Å |
Format |
Column |
Surface Area |
185 |
System |
SFC, UPC2 |
Particle Technology |
BEH |
Technique |
SFC, SFC/MS |
Inner Diameter |
3 mm |
Length |
100 mm |
Carbon Load |
9 % |
eCord |
Yes |
UNSPSC |
41115711 |
Brand |
Viridis |
Product Type |
Columns |
Units per Package |
1 pk |
Viridis BEH 2-Ethylpyridine Column, 130Å, 1.7 µm, 3 mm X 100 mm, 1/pk
The Viridis Silica columns are designed to be very repeatable and predictable, with strict product criteria and very little metal content, and are based on Waters' significant experience in chromatographic silica manufacturing. They are available for both analytical and purification preparative column dimensions. The lab equipment is commonly used in archival SFC separations, both with and without additives, displaying good retention, peak shape, and selectivity.
The Viridis sub-2-m and 3.5-m columns, which were designed and tested for the ACQUITY UPC2 system, display outstanding efficiency and resolution. Under SFC conditions, the decrease and control of surface silanol activity on Viridis particles results in good peak forms.
The Viridis brand contains a broad selection of lab equipment across different variations and chemistries to ensure you have the right products to choose from. You can find the complete range on our website, which also allows you to shop for lab equipment directly from us. This is for your convenience as you will be able to browse for products that work well together, and you will also have peace of mind, knowing that you are purchasing authentic Waters merchandise at the best available market rates.
The Viridis packing materials were created expressly for use with the ACQUITY UPLC System and are made in a cGMP, ISO 9001 certified facility with ultra-pure reagents.
Each batch of Viridis packing material is chromatographically tested with acidic, basic, and neutral analytes, with results held within narrow specification ranges to ensure outstanding, repeatable performance. On the eCordTM Intelligent Chip, each column is independently examined, and a Performance Chromatogram and Certificate of Batch Analysis are provided.
Explore other pieces of lab equipment by Waters, including the Viridis BEH OBD Prep Column, 130Å, 5 µm, 10 mm X 150 mm, 1/pk, which can be used in conjunction with this product and many others like it.
What Maximum Pressure Can The Viridis BEH 2-Ethylpyridine Column Tolerate?
The Viridis BEH 2-Ethylpyridine Column listed here is able to withstand up to 6000 psi (415 Bar) pressure easily. However, Waters recommends that to ensure maximum performance and an enhanced lifetime of the column, pressures between 4,000-5,000 psi be used.