Chemistry |
Phenyl |
Separation Mode |
Reversed Phase |
Particle Substrate |
Hybrid |
pH Range Min |
1 pH |
pH Range Max |
11 pH |
Maximum Pressure |
18000 psi (1240 Bar) |
Endcapped |
Yes |
Bonding Technology |
Phenyl-Hexyl |
Silanol Activity |
Low |
Particle Shape |
Spherical |
Particle Size |
2.5 µm |
Endfitting Type |
Parker-style |
Pore Size |
130 Å |
Format |
Column |
Surface Area |
185 |
System |
UHPLC, UPLC |
Particle Technology |
CSH |
USP Classification |
L11 |
Inner Diameter |
3 mm |
Length |
150 mm |
Carbon Load |
14 % |
eCord |
Yes |
UNSPSC |
41115709 |
Brand |
XSelect |
Product Type |
Columns |
Units per Package |
1 pk |
XSelect CSH Phenyl-Hexyl Column, 130Å, 2.5 µm, 3 mm X 150 mm, 1/pk
For the best separation performance, robustness, and throughput for HPLC tests that are fully compatible with all HPLC, UPLC, and UHPLC technologies, use the XSelect CSH Phenyl-Hexyl Column. The XSelect CSH Phenyl-Hexyl Column offers superior performance and comparable back pressure when compared to core-shell columns. The analytical column can also offer increased loading capacity and particle size scalability, both of which are features of fully-porous particle columns.
Leverage the XSelect CSH Phenyl-Hexyl Column, a useful tool for method development because it provides you with alternate analyte selectivity compared to conventional reversed-phase columns. The trifunctionally linked C6 phenyl-ligand, a strong, low-bleed sorbent that selectively retains polyaromatic chemicals through pi-pi interactions, is used in the lab equipment. The XSelect CSH Phenyl-Hexyl Column emphasizes reversed-phase contacts more so than secondary Lewis-base interactions, in contrast to fluorinated phenyl columns. The Charged Surface Hybrid (CSH) technology, which substantially enhances all aspects of liquid chromatography performance in acidic, low ionic strength mobile phases, is incorporated into the lab equipment. Because of this, purchasing the XSelect CSH Phenyl-Hexyl Column is essential.
You can take full advantage of technique development freedom because the XSelect CSH Phenyl-Hexyl Column was built to optimize selectivity differences, particularly when utilizing low pH mobile phases. The XSelect CSH Phenyl-Hexyl Column's non-end-capped sorbent enhances the retention of acidic chemicals. The analytical lab equipment provides remarkable separation performance, resilience, and throughput for HPLC tests while permitting a smooth transition route toward UPLC adoption because it is housed in ultra-low dispersion hardware.
Visit our website to browse for lab equipment and locate items that can be used in conjunction with the items listed below.
Protect your XSelect CSH column from the unwanted contaminants that interfere with the analysis results,using the XSelect CSH Phenyl-Hexyl XP VanGuard Cartridge, 130Å, 2.5 µm, 2.1 mm X 5 mm, 3/pk. The cartridge is made using the same packing materials as the column, making them ideally suited to provide accurate results working in tandem.
Does The XSelect CSH Phenyl-Hexyl Column Have Any Lower And Upper pH Limits?
The Waters XSelect CSH Phenyl-Hexyl Column offers a lower pH limit of 1, and a higher pH of 11.
What Is The Maximum Pressure That The XSelect CSH Phenyl-Hexyl Column Can Tolerate?
The Waters XSelect CSH Phenyl-Hexyl Column is able to sustain a maximum of 18,000 psi (1240 Bar) pressure.