Chemistry |
C18 |
Separation Mode |
Reversed Phase |
Particle Substrate |
Hybrid |
pH Range Min |
1 pH |
pH Range Max |
11 pH |
Endcapped |
Yes |
Silanol Activity |
Low |
Molecular Weight Range Min |
1000 |
Molecular Weight Range Max |
15000 |
Particle Shape |
Spherical |
Particle Size |
1.7 µm |
Endfitting Type |
Parker-style |
Pore Size |
130 Å |
QC Tested |
Peptide |
Format |
Column |
Surface Area |
185 |
System |
UHPLC, UPLC |
Particle Technology |
CSH |
USP Classification |
L1 |
Inner Diameter |
1 mm |
Length |
100 mm |
Carbon Load |
15 % |
UNSPSC |
41115709 |
Application |
Peptide |
Brand |
ACQUITY UPLC |
Product Type |
Columns |
Units per Package |
1 pk |
ACQUITY UPLC Peptide CSH C18 Column, 130Å, 1.7 µm, 1 mm X 100 mm, 1K - 15K, 1/pk
The universal ACQUITY UPLC Peptide CSH C18 Column provides alternate selectivity that is ideal for a wide range of chemicals. Because it is based on the Charged Surface Hybrid (CSH) particle platform, the analytical column has outstanding peak shape and enhanced loading capacity. This is especially true for basic chemicals in the mobile phase when the pH is low, and the ionic strength is low. Depend on the lab equipment's broad selectivity range in a variety of applications. The ACQUITY UPLC Peptide CSH C18 Column not only has outstanding selectivity, but it also has a high standard of necessary performance features such as superior peak shape for basic chemicals, reduced column bleed, and efficiency.
Waters ACQUITY UPLC CSH130 C18 1.7 m particles have a low and precisely specified concentration of positive charges, resulting in a peptide peak shape that is comparable to that of FA or TFA-containing mobile phases. The fact that the lab equipment's performance isn't overly reliant on strong ion pairing agents makes it excellent for LC or LC-MS applications.
Avoid the drawbacks of TFA while still achieving the best outcomes achievable with TFA. This is because the ACQUITY UPLC Peptide CSH C18 Column uses CSH technology to simulate TFA (trifluoroacetic acid) peak shape without actually using TFA. A more MS-friendly mobile phase, such as formic acid, is used in the column. Because formic acid does not have the lingering chromatographic effects of an ion-pairing agent, the lab equipment allows for faster and easier technique development.
Using the ACQUITY UPLC Peptide CSH C18 Column, develop robust and simply transferable procedures that can be easily replicated even if your laboratories are located in different parts of the world. The lab equipment was created with a global user base in mind.
Only the strictest conditions are used to manufacture the ACQUITY UPLC Peptide CSH C18 Column, as with all Waters lab equipment. You may rest assured that the lab equipment will not need to be replaced frequently and will produce consistent findings year after year.
You may also want to invest in the Cytochrome C Digestion Standard.
What pH Range Is Offered By The ACQUITY UPLC Peptide CSH C18 Column?
The ACQUITY UPLC Peptide CSH C18 Column listed here works well across the 1-11 pH range.