Chemistry |
C18 |
Separation Mode |
Reversed Phase |
Particle Substrate |
Hybrid |
pH Range Min |
1 pH |
pH Range Max |
10 pH |
Maximum Pressure |
10000 psi (690 Bar) |
Endcapped |
Yes |
Silanol Activity |
Low |
Particle Shape |
Spherical |
Particle Size |
1.7 µm |
Pore Size |
300 Å |
QC Tested |
Peptide |
Format |
Separation Device |
Surface Area |
90 |
System |
Nano/Micro |
Particle Technology |
BEH |
USP Classification |
L1 |
Inner Diameter |
150 µm |
Length |
50 mm |
Carbon Load |
12 % |
UNSPSC |
41115854 |
Application |
Peptide |
Brand |
iKey |
Product Type |
Columns |
Units per Package |
1 pk |
iKey Peptide BEH C18 Separation Device, 300Å, 1.7 µm, 150 µm X 50 mm, 1/pk
One of the enabling technologies for the ionKey/MS system is the iKey Separation device. Traditional fittings are no longer required, thanks to the ingenious iKey, which also makes using the microflow-LC system a lot easier. The iKey, which is offered in lengths of 50 mm and 100 mm and has an internal diameter of 150 m, pushes microflow LC into the center of attention in chromatographic labs.
The iKey Separation Device, which is part of the ionKey/MS System, has all of the fluid connections, electronics, ESI interface, column heaters, eCords, and chemicals required to carry out HPLC separations. It eliminates the requirement for conventional fittings and columns, streamlining the user experience. Regardless of user skill level, the plug-and-play nature of the iKey reduces user-dependent variation in results that frequently arises in conventional micro-flow LC-MS investigations.
To locate different items that are compatible with the iKey Peptide BEH C18 Separation Device, please visit our website or download our brochure. You can simply shop for lab equipment on our website and get in touch with us if you have any questions. You can speak with a staff member with any questions or issues you may have.
You might also be interested in nanoEase M/Z Symmetry C18 Trap Column, 100Å, 5 µm, 300 µm X 25 mm, 1/pk The nanoEaseTM M/Z columns offer the highest sensitivity, resolution, and repeatability for the identification and characterization of proteins as well as superior performance for liquid chromatographic separation at the nano- to microscale. The 300m ID columns have the same ease of use as more conventional columns and are constructed using an extremely low dispersion column design. They can endure operating pressure of 15 kpsi, handle pressure variations during injection with ease, and provide an outstanding lifetime, just like all M/Z columns. It's crucial to make the right connections to reduce peak tailing and inefficient operation in order to obtain optimal performance. Waters' patented BEH Technology 130A pore, C18, 1.7um particles are included in this particular offering. Before being QC recognized as a Peptide separation column, each batch is QC tested utilizing a gradient separation of a tryptic digest of cytochrome c.
What Effect Does Temperature Have on Liquid Chromatography?
Chromatography involves a series of equilibrium processes where analytes are either dissolved in the mobile phase or adsorbed to the stationary phase of the column. Increasing the temperature promotes faster interchange of analytes between the mobile and stationary phases, leading to accelerated analysis.