Separation Mode |
SEC/GPC |
Particle Substrate |
Hybrid |
pH Range Min |
1 pH |
pH Range Max |
12 pH |
Endcapped |
No |
Silanol Activity |
Low |
Molecular Weight Range Min |
1000 |
Molecular Weight Range Max |
30000 |
Particle Shape |
Spherical |
Particle Size |
2.5 µm |
Endfitting Type |
Parker-style |
Pore Size |
125 Å |
Format |
Column |
System |
APC |
Particle Technology |
BEH |
Technique |
GPC |
Inner Diameter |
4.6 mm |
Length |
150 mm |
eCord |
Yes |
UNSPSC |
41115709 |
Brand |
ACQUITY APC |
Product Type |
Columns |
Units per Package |
1 pk |
ACQUITY APC BEH Column, 125Å, 2.5 µm, 4.6 mm X 150 mm, 1K - 30K, 1/pk
Use the Waters ACQUITY APC BEH Column in your lab to conduct a range of separations. The lab equipment has been optimized to provide highly efficient size-based separations for organic solvent-soluble polymer characterization. The analytical column uses a sorbent that utilizes Waters’ patented Ethylene Bridged Hybrid (BEH) technology which provides a mechanical strong packed bed that resists shrinking and swelling for easy mobile phase solvent switching. This particular listing has an expected molecular weight range for this column is approximately 1,000 - 30,000 g/mole.
The ACQUITY APC BEH Column has been designed to be used in conjunction with the ACQUITY™Advanced Polymer Chromatography™ (APC™) System and delivers maximum separation performance when used with it. The tubing and connectors that are present in the ACQUITY APC System have been designed to meet stringent tolerances to minimize extra-column volume within the system.
Take advantage of the distinctive features of the column. The ACQUITY APC BEH Column is easily able to provide you with mechanical strength, packed-bed stability, and high separation efficiency due to the sub-3-µm ethylene bridged hybrid (BEH) particles used in the packing of the lab equipment. By leveraging these attributes, the lab equipment can deliver superior chromatographic performance for all polymer classes, including low molecular weight aqueous and organic soluble polymers. In addition to this, the high-coverage trimethyl silane bonded to a BEH substrate of the ACQUITY APC BEH Column makes it possible for the column to be used for extended temperatures separations of up to 90 °C in organic solvents.
The ACQUITY APC BEH Column is manufactured in our ISO 9001 facility and is held to narrow specification ranges to ensure reproducible performance, like all the lab equipment that is manufactured by Waters. In addition to this, every column is individually tested, and a Certificate of Batch Analysis is provided on the attached eCord™ Intelligent Chip.
Find the complete range of ACQUITY APC columns as well as their compatible products on our website. Through our online store, you can also shop for lab equipment directly from us.
We also recommend that you store your analytes in a safe and inert vessel by investing in the LCGC Certified Clear Glass 12 x 32 mm Screw Neck Vial, with Cap and PTFE/Silicone Septum, 2 mL Volume, 100/pk.
Is There A Recommended pH Range For The ACQUITY APC BEH Column?
The ACQUITY APC BEH Column listed here works well between the 1-12 pH Range.