Separation Mode |
SEC/GPC |
Particle Substrate |
Hybrid |
pH Range Min |
1 pH |
pH Range Max |
12 pH |
Endcapped |
No |
Silanol Activity |
Low |
Molecular Weight Range Min |
300000 |
Molecular Weight Range Max |
2000000 |
Particle Shape |
Spherical |
Particle Size |
2.5 µm |
Endfitting Type |
Parker-style |
Pore Size |
900 Å |
Format |
Column |
System |
APC |
Particle Technology |
BEH |
Technique |
GPC |
Inner Diameter |
4.6 mm |
Length |
150 mm |
eCord |
Yes |
UNSPSC |
41115709 |
Brand |
ACQUITY APC |
Product Type |
Columns |
Units per Package |
1 pk |
ACQUITY APC XT BEH Column, 900Å, 2.5 µm, 4.6 mm X 150 mm, 300K - 2M, 1/pk
You can increase the variety of lab equipment in your inventory by incorporating the Waters ACQUITY APC XT BEH Column, which was created to provide extremely effective size-based separations for organic solvent-soluble polymer characterization. The analytical column's sorbent utilizes Waters' proprietary Ethylene Bridge Hybrid (BEH) technology, which offers a mechanically robust packed bed that prevents shrinking and swelling for effective mobile phase solvent switching.
The packing of the ACQUITY APC XT BEH Column contains 2.5 µm ethylene bridged hybrid (BEH) particles, which are responsible for the column's outstanding separation efficiency, packed-bed stability, and mechanical strength. Due to these characteristics, the lab apparatus can offer higher chromatographic performance for all polymer classes, including low molecular weight water and organic soluble polymers.
For the characterization of organic solvent-soluble polymers, ACQUITY APC XT columns are intended to offer highly effective size-based separations. The sorbent uses unique Ethylene Bridge Hybrid (BEH) technology to offer a mechanical robust packed bed that resists shrinking and swelling for easy mobile phase solvent switching. The predicted molecular weight range for this column is roughly 300,000 - 2,000,000 g/mole.
Use the ACQUITY APC XT BEH Column with the ACQUITY Advanced Polymer ChromatographyTM (APC) System since it was designed to work with the system and gives the greatest separation results. To reduce extra-column space within the system, the ACQUITY APC System uses tubing and connectors that have been built to fulfill stringent specifications.
Like all of Waters' lab equipment, the ACQUITY APC BEH Column is manufactured in our ISO 9001-certified facility and is held to strict specification guidelines to ensure reliable performance. On the website, you have the option to shop for lab equipment directly and contact us with any inquiries. You can talk to a member of our staff about your questions and concerns at one of our many offices across the world.
You might also want to check out ACQUITY APC Polystyrene High MW Calibration Kit;The molecular weight range of the ACQUITY APC XT Columns was specially matched by APC Calibration Standards. Since ACQUITY APC Calibration Standards offer the appropriate number of data points for the specified MW range, they eliminate the need to manually build unique standard calibration mixes. In 12 x 32 mm transparent glass vials with PTFE/silicone septa, the calibration standards are packaged. The cap color represents the MW standards in the vial. Simply add solvent to the vial to dissolve the standards and place the vial in the autosampler, following the instructions provided.
What Are The pH Limitations Of The ACQUITY APC XT BEH Column?
The ACQUITY APC XT BEH Column can be used within the 1 to 12 pH range.