Chemistry |
Amide |
Separation Mode |
Hydrophilic Interaction (HILIC) |
Particle Substrate |
Hybrid |
pH Range Min |
2 pH |
pH Range Max |
11 pH |
Maximum Pressure |
18000 psi (1240 Bar) |
Endcapped |
No |
Silanol Activity |
Low |
Molecular Weight Range Min |
1000 |
Molecular Weight Range Max |
150000 |
Particle Shape |
Spherical |
Particle Size |
2.5 µm |
Endfitting Type |
Parker-style |
Pore Size |
130 Å |
QC Tested |
Glycan |
Format |
Column |
Surface Area |
185 |
System |
UHPLC |
Particle Technology |
BEH |
USP Classification |
L68 |
Inner Diameter |
2.1 mm |
Length |
100 mm |
Carbon Load |
12 % |
UNSPSC |
41115709 |
Application |
Glycan |
Brand |
XBridge |
Product Type |
Columns |
Units per Package |
1 pk |
XBridge Glycan BEH Amide Column, 130Å, 2.5 µm, 2.1 mm X 100 mm, 1K - 150K, 1/pk
In order to provide remarkable stability and adaptability in HILIC separations lab equipment, the XBridge Glycan BEH Amide Column, which is based on Waters' novel ethylene bridged hybrid (BEH) particle, uses a chemically stable, trifunctionally bonded amide phase. In order to preserve and separate highly polar compounds in HILIC stationary phases, Waters created this capacity. Scientists may easily transfer separations between HPLC and UPLC technology platforms since the XBridge Glycan BEH Amide Column has the same selectivity as the ACQUITY UPLC BEH Amide columns.
To ensure uniformity from batch to batch and nearly similar separated glycan profiles, each batch of BEH Glycan material undergoes quality control testing using the 2-AB labeled Waters Glycan Performance. In addition, chromatographers can now choose the best LC-based technology to meet their specific application needs for individually released glycan analysis, as well as lab equipment to guarantee very comparable results. Three highly scalable particle sizes of the Waters BEH-based glycan chemistry are offered to accommodate UPLC and HPLC applications. Through our online store, you may find out more about the many lab equipment options. The online store also enables you to buy lab equipment directly from us and match appropriate goods for the optimal analytical experience.
Retaining highly polar compounds like sugars and carbohydrates requires the Waters XBridge Glycan BEH Amide Column. The lab equipment enables the separation of polar analytes according to a variety of factors, including polarity, structural moiety, and pKa. A trifunctionally connected, chemically stable amide phase that is stable over a broad pH range is provided by the XBridge Glycan BEH Amide Column.
Protect your column from harm using the XBridge BEH Amide XP VanGuard Cartridge, 130Å, 2.5 µm, 2.1 mm X 5 mm, 3/pk. The cartridge is made using the exact packing materials that are used in the column and works to filter out any unwanted contaminants from the mobile stream.
What Is The pH Range Offered By The XBridge Glycan BEH Amide Column?
The Waters XBridge Glycan BEH Amide Column listed here is able to conduct analysis within the 2-11 pH range.
What Is The Maximum Pressure That The XBridge Glycan BEH Amide Column Can Sustain?
This particular XBridge Glycan BEH Amide Column is able to tolerate a maximum pressure of up to 18,000 psi (1240 Bar).