Chemistry |
C18 |
Separation Mode |
Reversed Phase |
Particle Substrate |
Silica |
pH Range Min |
2 pH |
pH Range Max |
8 pH |
Maximum Pressure |
18000 psi (1240 Bar) |
Endcapped |
Yes |
Bonding Technology |
T3 |
Silanol Activity |
Medium |
Particle Shape |
Spherical |
Particle Size |
3 µm |
Endfitting Type |
Waters |
Pore Size |
100 Å |
Format |
VanGuard Cartridge |
Surface Area |
330 |
System |
HPLC |
Particle Technology |
Silica |
USP Classification |
L1 |
Inner Diameter |
2.1 mm |
Length |
5 mm |
Carbon Load |
14 % |
UNSPSC |
41115709 |
Brand |
Atlantis |
Product Type |
Guards |
Units per Package |
3 pk |
Atlantis Silica T3 VanGuard Cartridge, 100Å, 3 µm, 2.1 mm X 5 mm, 3/pk
Use the Atlantis Silica T3 VanGuard Cartridge to extend the lifetime of your analytical column. The lab equipment works in conjunction with the analytical column and improves its performance by removing chemical and particulate contamination from the mobile phase stream. This cartridge is optimized to protect all 2.1 mm and 3.0 mm I.D. Atlantis T3 analytical columns contain 3 µm sorbent particles.
The Waters Atlantis Silica T3 VanGuard Cartridge has been designed to be compatible with the Atlantis T3 Columns for reversed-phase Liquid Chromatography. The lab equipment is optimized to deliver the same level of performance as the analytical column as it is made using identical packing materials. The VanGuard Cartridge is a single unit that can be attached directly to the inlet side of an Atlantis T3 Column.
Like all equipment that Waters manufactures, the Atlantis Silica T3 VanGuard Cartridge is manufactured under the strictest cGMP, ISO 9001 conditions, and each unit is tested and certified for its use, guaranteeing that it will deliver optimal performance and enhance the selectivity, sensitivity, and speed of your analysis. Every step of the manufacturing process is strictly controlled and monitored to ensure that you receive only the best quality equipment for your lab.
Through the use of the Atlantis Silica T3 VanGuard Cartridge, your UPLC analytical columns last longer without compromising their chromatographic analytical performance. This is achieved by removing unwanted pollutants from the columns and maintaining their UPLC, UHPLC, and HPLC separation efficiency.
The Atlantis Silica T3 VanGuard Cartridge is designed for routine use and can tolerate pressures up to 18000 psi (1240 bar) in applications run on the ACQUITY UPLC System. The product listed here contains Waters patented BEH Technology C18, 100A pore, and 3 µm particles. The lab equipment also works across a wide pH range of 2-8.
Learn about the complete Waters product portfolio by browsing through our website. You will find products to meet any analytical need and also the research and technology behind them. In addition, you can use the website to shop for lab equipment.
Also explore the LCGC Certified Clear Glass 12 x 32 mm Screw Neck Vial, with Cap and Preslit PTFE/Silicone Septum, 2 mL Volume, 100/pk.
What Can Be Separated By Liquid Chromatography?
Liquid Chromatography is useful for the separation of ions or molecules that are dissolved in a solvent.