Chemistry |
C8 |
Separation Mode |
Reversed Phase |
Particle Substrate |
Silica |
pH Range Min |
2 pH |
pH Range Max |
8 pH |
Maximum Pressure |
18000 psi (1240 Bar) |
Endcapped |
Yes |
Silanol Activity |
Low |
Particle Shape |
Spherical |
Particle Size |
3.5 µm |
Endfitting Type |
Waters |
Pore Size |
100 Å |
Format |
VanGuard Cartridge |
Surface Area |
110 |
System |
HPLC |
USP Classification |
L7 |
Inner Diameter |
3.9 mm |
Length |
5 mm |
Carbon Load |
12 % |
UNSPSC |
41115709 |
Brand |
Symmetry |
Product Type |
Guards |
Units per Package |
3 pk |
Symmetry C8 VanGuard Cartridge, 100Å, 3.5 µm, 3.9 mm X 5 mm, 3/pk
The Symmetry C8 VanGuard Cartridge is a highly efficient and reliable lab equipment designed for high-performance liquid chromatography (HPLC) applications. This cartridge is specifically engineered to enhance the performance and lifespan of the Symmetry C8 analytical column, extending its analytical capabilities and ensuring consistent, high-quality results. Each pack includes three cartridges, ensuring convenience and flexibility for your analytical experiments.
The Symmetry C8 VanGuard Cartridge serves as a guard column, protecting the analytical column from sample matrix components and contaminants that may adversely affect column performance and lifespan. The lab equipment efficiently traps and removes these interfering substances, preventing their accumulation in the analytical column and extending its longevity.
Depend on the Symmetry C8 VanGuard Cartridge as it is known for its exceptional reproducibility, reliability, and long column lifetime. It is compatible with a variety of solvents and can withstand high-pressure conditions, making it a valuable tool for method development and optimization.
Whether you are performing routine analysis, method development, or complex sample profiling, the Symmetry C8 VanGuard Cartridge helps in delivering consistent and reliable results by protecting the analytical column. It offers excellent peak shapes, high resolution, and enhanced sensitivity for your chromatographic analyses by ensuring there is no interference in the analyses.
The Symmetry C8 VanGuard Cartridge features a stationary phase made of C8 (octyl) bonded to silica support, providing a hydrophobic interaction mechanism for the separation of various analytes. The C8 phase offers excellent selectivity, making it ideal for a wide range of applications, including pharmaceutical, environmental, and chemical analysis.
We recommend that you also explore the LCGC Certified Clear Glass 12 x 32 mm Screw Neck Vial, with Cap and Preslit PTFE/Silicone Septum, 2 mL Volume, 100/pk.
What Is The Recommended Flow Rate For The Symmetry C8 VanGuard Cartridge?
The recommended flow rate for the Symmetry C8 VanGuard Cartridge is between 0.1 and 1 mL/min. However, the maximum pressure limit for the cartridge is 6000 psi, so the flow rate should be adjusted accordingly to stay within that limit.
What Is The Maximum Operating Pressure Of The Symmetry C8 VanGuard Cartridge?
The maximum operating pressure of the Symmetry C8 VanGuard Cartridge is 6000 psi. It is important not to exceed this limit, as doing so can damage the column and affect the quality of the separation. To ensure optimal performance, it is recommended to use the column within its specified pressure range.