SKU: 186007735
Symmetry C8 VanGuard Cartridge, 100Å, 3.5 µm, 3.9 mm X 5 mm, 3/pk

Symmetry C8 VanGuard Cartridge | 100Å | 186007735


Streamline Purchasing with Customized Quotes

Streamline Purchasing with Customized Quotes

Shop on Waters.com and add items to your cart

Navigate to the Shopping Cart

Select Request a Quote to get your quote instantly


Product Description

Symmetry C8 VanGuard Cartridges are used to extend analytical column lifetime and performance by removing particulate contamination from the mobile phase stream. This cartridge is optimized to protect all 3.9 mm and 4.6 mm I.D. Symmetry C8 analytical columns containing 3.5 µm sorbent particles.

Specifications

  • Chemistry

    C8

  • Separation Mode

    Reversed Phase

  • Particle Substrate

    Silica

  • pH Range Min

    2 pH

  • pH Range Max

    8 pH

  • Maximum Pressure

    18000 psi (1240 Bar)

  • Endcapped

    Yes

  • Silanol Activity

    Low

  • Particle Shape

    Spherical

  • Particle Size

    3.5 µm

  • Endfitting Type

    Waters

  • Pore Size

    100 Å

  • Format

    VanGuard Cartridge

  • Surface Area

    110

  • System

    HPLC

  • USP Classification

    L7

  • Inner Diameter

    3.9 mm

  • Length

    5 mm

  • Carbon Load

    12 %

  • UNSPSC

    41115709

  • Brand

    Symmetry

  • Product Type

    Guards

  • Units per Package

    3 pk

Product Support

Documents

Documents



What do you want to do?

What do you want to do?

Related Products

Back To Top Back To Top

Symmetry C8 VanGuard Cartridge, 100Å, 3.5 µm, 3.9 mm X 5 mm, 3/pk

The Symmetry C8 VanGuard Cartridge is a highly efficient and reliable lab equipment designed for high-performance liquid chromatography (HPLC) applications. This cartridge is specifically engineered to enhance the performance and lifespan of the Symmetry C8 analytical column, extending its analytical capabilities and ensuring consistent, high-quality results. Each pack includes three cartridges, ensuring convenience and flexibility for your analytical experiments.

The Symmetry C8 VanGuard Cartridge serves as a guard column, protecting the analytical column from sample matrix components and contaminants that may adversely affect column performance and lifespan. The lab equipment efficiently traps and removes these interfering substances, preventing their accumulation in the analytical column and extending its longevity.

Depend on the Symmetry C8 VanGuard Cartridge as it is known for its exceptional reproducibility, reliability, and long column lifetime. It is compatible with a variety of solvents and can withstand high-pressure conditions, making it a valuable tool for method development and optimization.

Whether you are performing routine analysis, method development, or complex sample profiling, the Symmetry C8 VanGuard Cartridge helps in delivering consistent and reliable results by protecting the analytical column. It offers excellent peak shapes, high resolution, and enhanced sensitivity for your chromatographic analyses by ensuring there is no interference in the analyses.

The Symmetry C8 VanGuard Cartridge features a stationary phase made of C8 (octyl) bonded to silica support, providing a hydrophobic interaction mechanism for the separation of various analytes. The C8 phase offers excellent selectivity, making it ideal for a wide range of applications, including pharmaceutical, environmental, and chemical analysis.

We recommend that you also explore the LCGC Certified Clear Glass 12 x 32 mm Screw Neck Vial, with Cap and Preslit PTFE/Silicone Septum, 2 mL Volume, 100/pk.

What Is The Recommended Flow Rate For The Symmetry C8 VanGuard Cartridge?

The recommended flow rate for the Symmetry C8 VanGuard Cartridge is between 0.1 and 1 mL/min. However, the maximum pressure limit for the cartridge is 6000 psi, so the flow rate should be adjusted accordingly to stay within that limit.

What Is The Maximum Operating Pressure Of The Symmetry C8 VanGuard Cartridge?

The maximum operating pressure of the Symmetry C8 VanGuard Cartridge is 6000 psi. It is important not to exceed this limit, as doing so can damage the column and affect the quality of the separation. To ensure optimal performance, it is recommended to use the column within its specified pressure range.