Chemistry |
C18 |
Separation Mode |
Reversed Phase |
Particle Substrate |
Silica |
pH Range Min |
2 pH |
pH Range Max |
8 pH |
Maximum Pressure |
18000 psi (1240 Bar) |
Endcapped |
Yes |
Bonding Technology |
Shield RP18 |
Silanol Activity |
Low |
Particle Shape |
Spherical |
Particle Size |
3.5 µm |
Endfitting Type |
Waters |
Pore Size |
100 Å |
Format |
VanGuard Cartridge |
Surface Area |
110 |
System |
HPLC |
USP Classification |
L1 |
Inner Diameter |
3.9 mm |
Length |
5 mm |
Carbon Load |
17 % |
UNSPSC |
41115709 |
Brand |
Symmetry |
Product Type |
Guards |
Units per Package |
3 pk |
Symmetry Shield RP18 VanGuard Cartridge, 100Å, 3.5 µm, 3.9 mm X 5 mm, 3/pk
The Waters Symmetry Shield RP18 VanGuard Cartridge serves its job by being placed between the injector and the analytical column. In order to improve the performance of the analytical column, the lab equipment blocks the entry of chemical impurities and suspended materials. All 3.9 mm and 4.6 mm I.D. Symmetry C18 analytical columns with 3.5 µm sorbent particles are specifically protected by this cartridge. The lab equipment can be used with the Waters Symmetry RP18 column because it is constructed from the same packing material.
You may be sure that the VanGuard Cartridge will preserve and perform your column for a long time because it is built with the same high-performance packing materials as all of Waters' analytical columns. The Symmetry Cartridge is dependable since it was designed and constructed specifically for situations demanding increased capacity for biological fluid cleanup and/or temperature control.
The Symmetry Shield RP18 VanGuard Cartridge, like all of Waters' other products, is produced in a cGMP, ISO 9001-certified facility using ultra-pure chemicals. This guarantees the exceptional quality and durability of Waters lab equipment. Additionally, each batch of Symmetry Shield RP18 VanGuard Cartridge packing material is chromatographically tested with acidic, basic, and neutral analytes, with the results held to the highest standards to guarantee reliable, consistent performance every time. Also, each piece of lab equipment is put through testing before being approved for use, ensuring that it will perform at its peak and increase the selectivity, sensitivity, and speed of your study.
You may also want to explore the LCGC Certified Clear Glass 12 x 32 mm Screw Neck Vial, with Cap and Preslit PTFE/Silicone Septum, 2 mL Volume, 100/pk. Waters' Clear glass vials are made of the most chemically inert glass that is currently available, making them a great option for analytical labs that demand high-quality test results.
Across What pH Range Does The Symmetry Shield RP18 VanGuard Cartridge Operate?
This particular Waters Symmetry Shield RP18 VanGuard Cartridge is able to conduct analysis within the 2-8 pH range.
What Maximum Pressure Is The Recommended For The Waters Symmetry Shield RP18 VanGuard Cartridge?
The Symmetry Shield RP18 VanGuard Cartridge listed here is able to sustain a maximum pressure of 18000 psi (1240 Bar).