Chemistry |
C8 |
Separation Mode |
Reversed Phase |
Particle Substrate |
Hybrid |
pH Range Min |
1 pH |
pH Range Max |
12 pH |
Maximum Pressure |
18000 psi (1240 Bar) |
Endcapped |
Yes |
Silanol Activity |
Low |
Particle Shape |
Spherical |
Particle Size |
2.5 µm |
Endfitting Type |
Parker-style |
Pore Size |
130 Å |
Format |
XP VanGuard Cartridge |
Surface Area |
185 |
System |
UHPLC, UPLC |
Particle Technology |
BEH |
USP Classification |
L7 |
Inner Diameter |
2.1 mm |
Length |
5 mm |
Carbon Load |
13 % |
UNSPSC |
41115709 |
Brand |
XBridge |
Product Type |
Guards |
Units per Package |
3 pk |
XBridge BEH C8 XP VanGuard Cartridge, 130Å, 2.5 µm, 2.1 mm X 5 mm, 3/pk
By eliminating particle pollution from the mobile phase stream, XBridge BEH C8 XP VanGuard Cartridges are utilized to increase analytical column lifetime and performance. All 2.1 mm and 3.0 mm I.D. XBridge BEH Phenyl analytical columns with 2.5 µm sorbent particles are protected by this specific cartridge.
To ensure that your UPLC XBridge BEH C8 analytical columns last longer without losing their chromatographic analytical performance, connect them to the XBridge BEH C8 XP VanGuard Cartridge. The lab equipment removes chemical and particle contaminants while maintaining the UPLC, UHPLC, and HPLC separation performance of the columns.
The XBridge BEH C8 XP VanGuard Cartridge was developed especially for use with Waters UPLC columns in reversed-phase liquid chromatography. Due to its design, the VanGuard Cartridge is a single component that can be mounted right away to the intake side of a Waters XBridge UPLC Column.
It is easy to set up and use the XBridge BEH C8 XP VanGuard Cartridge. It guards against possibly dangerous contaminants that could harm your XBridge BEH C8 Column. By removing any chemical and particle impurities that might be present in the mobile phase stream, the lab equipment enhances and optimizes the analytical performance of the column.
The XBridge BEH C8 XP VanGuard Cartridge is one of the first guard column devices designed expressly for everyday use and can sustain high pressures in applications run on the ACQUITY UPLC System when used in conjunction with your analytical column. This bundle includes 2.5 µm particles, 130 pore size, and Waters' patented BEH Technology. A peptide map is used in the quality control testing of each batch of the XBridge BEH C8 XP VanGuard Cartridge to ensure consistent performance and prolonged analytical column life. This ensures that the lab equipment will continue to function in the same manner for the duration of its lifespan.
Store your analytes in a safe and inert vessel by choosing the LCGC Certified Clear Glass 12 x 32 mm Screw Neck Vial, with Cap and Preslit PTFE/Silicone Septum, 2 mL Volume, 100/pk.
What Is The pH Range Offered By The XBridge BEH C8 XP VanGuard Cartridge?
The XBridge BEH C8 XP VanGuard Cartridge offers a broad operating pH range of 1-12.
What Is The Maximum Pressure That The XBridge BEH C8 XP VanGuard Cartridge Can Tolerate?
This XBridge BEH C8 XP VanGuard Cartridge is able to sustain up to 18,000 psi (1240 Bar) pressure.