Chemistry |
HILIC |
Separation Mode |
Hydrophilic Interaction (HILIC) |
Particle Substrate |
Hybrid |
pH Range Min |
1 pH |
pH Range Max |
9 pH |
Maximum Pressure |
18000 psi (1240 Bar) |
Endcapped |
No |
Silanol Activity |
Medium |
Particle Shape |
Spherical |
Particle Size |
3.5 µm |
Endfitting Type |
Waters |
Pore Size |
130 Å |
Format |
VanGuard Cartridge |
Surface Area |
185 |
System |
HPLC |
Particle Technology |
BEH |
USP Classification |
L3 |
Inner Diameter |
2.1 mm |
Length |
5 mm |
UNSPSC |
41115709 |
Brand |
XBridge |
Product Type |
Guards |
Units per Package |
3 pk |
XBridge BEH HILIC VanGuard Cartridge, 130Å, 3.5 µm, 2.1 mm X 5 mm, 3/pk
For reversed-phase liquid chromatography, the XBridge BEH HILIC VanGuard Cartridge has been specially created for use with Waters UPLC columns. The VanGuard Cartridge is a standalone component that may be fastened directly to the intake side of a Waters XBridge UPLC Column, thanks to its unique design. This lab equipment is optimized to protect all 2.1 mm and 3.0 mm I.D. XBridge BEH HILIC analytical columns containing 3.5 µm sorbent particles.
It is simple to install and practical to use the XBridge BEH HILIC VanGuard Cartridge. It guarantees the safety of your XBridge BEH HILIC Column from harmful impurities. The lab equipment boosts and improves the analytical performance of the column by filtering out any chemical and particle contaminants that may exist in the mobile phase stream.
By using the XBridge BEH HILIC VanGuard Cartridge, you can extend the lifespan of your UPLC XBridge BEH HILIC analytical columns without sacrificing their chromatographic analytical performance. While eliminating chemical and particle impurities from the columns, the Cartridge preserves the UPLC, UHPLC, and HPLC separation efficiency of the columns.
The XBridge BEH HILIC VanGuard Cartridge is one of the first guard column devices specifically created for everyday usage and can withstand high pressures in applications run on the ACQUITY UPLC System when used in conjunction with an analytical column. The item on this list contains 130-pore, 3.5 µm BEH Technology C18 particles, which are patented by Waters. Each batch of the XBridge BEH HILIC VanGuard Cartridge is QC tested using a peptide map to ensure that you get consistent performance and prolonged analytical column life. In this manner, you can be sure that the lab equipment will work consistently over its lifespan.
You may also want to explore the LCGC Certified Clear Glass 12 x 32 mm Screw Neck Vial, with Cap and Preslit PTFE/Silicone Septum, 2 mL Volume, 100/pk. Made using chemically inert and stable glass, the vial is the ideal storage unit for your analytes.
What Are The pH Limitations Of The XBridge BEH HILIC VanGuard Cartridge?
This particular XBridge BEH HILIC VanGuard Cartridge offers a broad pH range of 1-9 pH.
What Is The Maximum Pressure That The XBridge BEH HILIC VanGuard Cartridge Can Tolerate?
The XBridge BEH HILIC VanGuard Cartridge listed here can withstand up to 18000 psi (1240 Bar) pressure.