Chemistry |
HILIC |
Separation Mode |
Hydrophilic Interaction (HILIC) |
Particle Substrate |
Hybrid |
pH Range Min |
1 pH |
pH Range Max |
9 pH |
Maximum Pressure |
18000 psi (1240 Bar) |
Endcapped |
No |
Silanol Activity |
Medium |
Particle Shape |
Spherical |
Particle Size |
2.5 µm |
Endfitting Type |
Parker-style |
Pore Size |
130 Å |
Format |
XP VanGuard Cartridge |
Surface Area |
185 |
System |
UHPLC, UPLC |
Particle Technology |
BEH |
USP Classification |
L3 |
Inner Diameter |
2.1 mm |
Length |
5 mm |
UNSPSC |
41115709 |
Brand |
XBridge |
Product Type |
Guards |
Units per Package |
3 pk |
XBridge BEH HILIC XP VanGuard Cartridge, 130Å, 2.5 µm, 2.1 mm X 5 mm, 3/pk
The XBridge BEH HILIC XP VanGuard Cartridge was developed especially for use with Waters UPLC columns in reversed-phase liquid chromatography. Due to the design of the VanGuard Cartridge, it may be connected to the intake side of a Waters XBridge UPLC Column right away.
The lifespan and performance of analytical columns are improved by XBridge BEH Amide VanGuard Cartridges by removing particle pollution from the mobile phase stream. All XBridge BEH Amide analytical columns with 2.5 m sorbent particles and an I.D. of 2.1 mm and 3.0 mm are protected by this lab equipment.
It is easy to use and install the XBridge BEH HILIC XP VanGuard Cartridge. It defends against possibly dangerous contaminants for your XBridge BEH Amide Column. By removing any chemical and particle impurities that might be present in the mobile phase stream, the lab equipment enhances and optimizes the analytical performance of the column.
To ensure that your UPLC XBridge BEH Amide analytical columns last longer without sacrificing their chromatographic analytical performance, connect them to the XBridge BEH HILIC XP VanGuard Cartridge. The cartridge removes chemical and particle contaminants while maintaining the UPLC, UHPLC, and HPLC separation performance of the columns.
The XBridge BEH HILIC XP VanGuard Cartridge is one of the first guard column devices designed expressly for routine use and can sustain high pressures in applications run on the ACQUITY UPLC System when used in conjunction with your analytical column. These pieces of lab equipment feature Waters' patented BEH Technology C18, 130-pore, and 2.5 µm particles.To ensure consistent performance and longer analytical column life, each batch of the XBridge BEH HILIC XP VanGuard Cartridge is quality controlled and tested using a peptide map. This ensures that the lab equipment will continue to function in the same manner for the duration of its lifespan.
We recommend that you invest in the LCGC Certified Clear Glass 12 x 32 mm Screw Neck Vial, with Cap and Preslit PTFE/Silicone Septum, 2 mL Volume, 100/pk, in order to safely store your samples.
What Is The pH Limitation Of The XBridge BEH HILIC XP VanGuard Cartridge?
This particular XBridge BEH HILIC XP VanGuard Cartridge can work well within the 1-9 pH range.
Is There A Recommended Maximum Pressure For The XBridge BEH HILIC XP VanGuard Cartridge?
For the XBridge BEH HILIC XP VanGuard Cartridge listed here, the recommended maximum pressure is 18,000 psi (1240 Bar).