XTerra MS C18 VanGuard Cartridges are used to extend analytical column lifetime and performance by removing particulate contamination from the mobile phase stream. This cartridge is optimized to protect all 2.1 mm and 3.0 mm I.D. XTerra MS C18 analytical columns containing 3.5 µm sorbent particles.

Specifications

  • Chemistry

    C18

  • Separation Mode

    Reversed Phase

  • Particle Substrate

    Hybrid

  • pH Range Min

    1 pH

  • pH Range Max

    12 pH

  • Maximum Pressure

    18000 psi (1240 Bar)

  • Endcapped

    Yes

  • Bonding Technology

    MS C18

  • Silanol Activity

    Low

  • Particle Shape

    Spherical

  • Particle Size

    3.5 µm

  • Endfitting Type

    Waters

  • Pore Size

    125 Å

  • Format

    VanGuard Cartridge

  • Surface Area

    175

  • System

    HPLC

  • USP Classification

    L1

  • Inner Diameter

    2.1 mm

  • Length

    5 mm

  • Carbon Load

    16 %

  • UNSPSC

    41115709

  • Brand

    XTerra

  • Product Type

    Guards

  • Units per Package

    3 pk

Product Support

Documents

Documents



What do you want to do?

What do you want to do?

Related Products

Back To Top Back To Top

XTerra MS C18 VanGuard Cartridge, 125Å, 3.5 µm, 2.1 mm X 5 mm, 3/pk

To safeguard and increase the lifespan of your XTerra MS C18 analytical column, use the VanGuard Cartridge. The lab equipment enhances the performance of the analytical column by lowering particle contamination from the mobile phase stream. All 2.1 mm XTerra MS C18 analytical columns with a 3.5 µm sorbent particle size are compatible with this cartridge.

Operating and setting up the XTerra MS C18 VanGuard Cartridge is straightforward. It defends against possibly dangerous contaminants for your XTerra MS C18 Column. By removing any potential chemical and particle impurities from the mobile phase stream, the lab equipment increases and improves the analytical performance of the column.

To ensure that your UPLC XTerra MS C18 analytical columns last longer without sacrificing their chromatographic analytical performance, connect them to the XTerra MS C18 VanGuard Cartridge. The cartridge removes chemical and particle contaminants while maintaining the UPLC, UHPLC, and HPLC separation performance of the columns.

The XTerra MS C18 VanGuard Cartridge is one of the first guard devices created expressly for everyday use and can sustain high pressures in applications performed on the ACQUITY UPLC System when used in conjunction with your analytical column. To ensure consistent performance and longer analytical column life, each batch of the XTerra MS C18 VanGuard Cartridge undergoes quality control testing utilizing a peptide map. This ensures that the lab equipment will continue to function in the same manner for the duration of its lifespan.

The XTerra MS C18 VanGuard Cartridge was developed especially for use with Waters UPLC columns in reversed-phase liquid chromatography. Due to its design, the XTerra MS C18 VanGuard Cartridge is a single component that can be fitted right away to the intake side of a Waters XTerra UPLC Column.

You may also want to invest in the LCGC Certified Clear Glass 12 x 32 mm Screw Neck Vial, with Cap and Preslit PTFE/Silicone Septum, 2 mL Volume, 100/pk.

What Is The Recommended Working pH Range For The XTerra MS C18 VanGuard Cartridge?

Waters recommends a working pH range of 1-12 for the XTerra MS C18 VanGuard Cartridge listed here.

Is There A Maximum Pressure Recommended For The XTerra MS C18 VanGuard Cartridge?

The XTerra MS C18 VanGuard Cartridge listed here has a recommended maximum pressure of 18,000 psi (1240 Bar).