Product Description

XTerra Shield RP18 VanGuard Cartridges are used to extend analytical column lifetime and performance by removing particulate contamination from the mobile phase stream. This cartridge is optimized to protect all 3.9 mm and 4.6 mm I.D. XTerra Sheild RP18 analytical columns containing 5 µm sorbent particles.

Specifications

  • Chemistry

    C18

  • Separation Mode

    Reversed Phase

  • Particle Substrate

    Hybrid

  • pH Range Min

    2 pH

  • pH Range Max

    12 pH

  • Maximum Pressure

    18000 psi (1240 Bar)

  • Endcapped

    Yes

  • Bonding Technology

    Shield RP18

  • Silanol Activity

    Low

  • Particle Shape

    Spherical

  • Particle Size

    5 µm

  • Endfitting Type

    Waters

  • Pore Size

    125 Å

  • Format

    VanGuard Cartridge

  • Surface Area

    175

  • System

    HPLC

  • USP Classification

    L1

  • Inner Diameter

    3.9 mm

  • Length

    5 mm

  • Carbon Load

    15 %

  • UNSPSC

    41115709

  • Brand

    XTerra

  • Product Type

    Guards

  • Units per Package

    3 pk

Product Support

Documents

Documents



What do you want to do?

What do you want to do?

Related Products

Back To Top Back To Top

XTerra Shield RP18 VanGuard Cartridge, 125Å, 5 µm, 3.9 mm X 5 mm, 3/pk

Use the XTerra Shield RP18 VanGuard Cartridge to protect and extend the life of your XTerra Shield RP18 analytical column. By reducing particle contamination from the mobile phase stream, the lab equipment improves the analytical column's performance. This cartridge has been designed to work with all 3.9 mm and 4.6 mm I.D. XTerra Shield RP18 analytical columns with a 5 µm sorbent particle size.

The XTerra Shield RP18 VanGuard Cartridge is simple to set up and operate. It protects your XTerra Shield RP18 Column from potentially harmful pollutants. The lab equipment boosts and improves the analytical performance of the column by filtering out any chemical and particle contaminants that may be present in the mobile phase stream.

Connect your UPLC XTerra Shield RP18 analytical columns to the XTerra Shield RP18 VanGuard Cartridge to ensure that they survive longer without compromising their chromatographic analytical performance. The cartridge keeps the UPLC, UHPLC, and HPLC separation efficiency of the columns while eliminating chemical and particle impurities.

The XTerra RP18 VanGuard Cartridge, when used in conjunction with your analytical column, is one of the first guard column devices specifically built for routine usage and can withstand high pressures in applications run on the ACQUITY UPLC System. Each batch of the XTerra RP18 VanGuard Cartridge is QC tested using a peptide map to ensure consistent performance and increased analytical column life. This way, you can be sure that the lab equipment will work the same way for the rest of its life.

The XTerra Shield RP18 VanGuard Cartridge was created specifically for reversed-phase liquid chromatography with Waters UPLC columns. The VanGuard Cartridge is a single item that may be immediately attached to the intake side of a Waters XTerra UPLC Column due to its design.

You may also want to explore and invest in the LCGC Certified Clear Glass 12 x 32 mm Screw Neck Vial, with Cap and Preslit PTFE/Silicone Septum, 2 mL Volume, 100/pk. The vial is made using inert glass and stores your samples and analytes such that there is no contamination, ensuring you receive accurate analysis results.

What pH Does The XTerra Shield RP18 VanGuard Cartridge Support?

The XTerra Shield RP18 VanGuard Cartridge listed works well across a wide operating pH of 2-12.