Chemistry |
C18 |
Separation Mode |
Reversed Phase |
Particle Substrate |
Hybrid |
pH Range Min |
1 pH |
pH Range Max |
12 pH |
Temperature Limits |
80 C (Low pH)/60 C (High pH) |
Maximum Pressure |
6000 psi (415 Bar) |
Endcapped |
Yes |
Silanol Activity |
Low |
Particle Shape |
Spherical |
Particle Size |
5 µm |
Endfitting Type |
Waters |
Pore Size |
130 Å |
Format |
OBD Prep Column |
Surface Area |
185 |
System |
HPLC Preparative |
Particle Technology |
BEH |
Technique |
LC, LC/MS |
USP Classification |
L1 |
Inner Diameter |
10 mm |
Length |
150 mm |
Carbon Load |
18 % |
UNSPSC |
41115709 |
Brand |
XBridge |
Product Type |
Preparative Columns |
Units per Package |
1 pk |
XBridge BEH C18 OBD Prep Column, 130Å, 5 µm, 10 mm X 150 mm, 1/pk
Use the XBridge BEH C18 OBD Prep Column to be able to achieve lab-scale separations for higher throughput in a faster, more efficient manner. You can increase efficiency by using Optimum Bed Density (OBD) preparative columns. You can also immediately scale from UPLC or HPLC screening to lab-scale purification and increase productivity by scaling up screening processes. As a workhorse for HPLC method development, XBridge BEH C18 sorbent can be used across a wide range of mobile phase pH. The trifunctionally bonded C18 ligand provides you with a universal column for most HPLC separations and gives you the widest usable pH range, superior low pH stability, and ultra-low column bleed.
The Waters XBridge BEH C18 OBD Prep Column increases recoveries while increasing productivity. It is an essential piece of lab equipment since it allows for longer column lives, which means you do not have to replace the column as frequently, saving you money.
Waters patented the packing process and design of the XBridge BEH C18 OBD Prep Column, allowing you to achieve predictable, homogeneous density profiles across the column. It also eliminates the chance of cavities because there is no overcompression or non-uniform disturbance during the capping process.
The XBridge BEH C18 OBD Prep Column provides remarkable resistance to mechanical chromatographic bed failure. The lab equipment’s OBD design resists low solubility and pressure shocks caused by huge volumes of pure organic solvent. The Optimum Bed Density (OBD) design was created with the integrity and stability in mind for a preparative column utilized in quick, high-purity compound isolations. Additionally, make use of constant column-to-column performance to save money by extending lifetimes. This is accomplished by employing ultra-pure reagents and adhering to the most stringent production standards, such as cGMP and ISO 9001:2000.
Protect your prep column by investing in the XBridge BEH C18 Prep Guard Cartridge, 130Å, 5 µm, 10 mm X 10 mm, 1/pk.
What Temperature Limits Does The XBridge BEH C18 OBD Prep Column Allow?
The XBridge BEH C18 OBD Prep Column listed here works well within the 80 C (Low pH)/60 C (High pH) temperature range.
Is There A pH Range For The XBridge BEH C18 OBD Prep Column?
The XBridge BEH C18 OBD Prep Column listed here has a minimum pH of 1 and a maximum pH of 12 pH.