Chemistry |
Phenyl |
Separation Mode |
Reversed Phase |
Particle Substrate |
Silica |
pH Range Min |
2 pH |
pH Range Max |
8 pH |
Temperature Limits |
45 C |
Maximum Pressure |
18000 psi (1240 Bar) |
Endcapped |
Yes |
Bonding Technology |
Phenyl-Hexyl |
Silanol Activity |
Low |
Particle Shape |
Spherical |
Particle Size |
1.6 µm |
Endfitting Type |
Parker-style |
Pore Size |
90 Å |
Format |
Column |
Surface Area |
100 |
System |
UHPLC, UPLC |
Particle Technology |
Solid Core |
USP Classification |
L11 |
Inner Diameter |
2.1 mm |
Length |
50 mm |
Carbon Load |
5.9 % |
eCord |
Yes |
UNSPSC |
41115709 |
Brand |
CORTECS |
Product Type |
Columns |
Units per Package |
1 pk |
CORTECS Phenyl Column, 90Å, 1.6 µm, 2.1 mm X 50 mm, 1/pk
Use the Waters CORTECS Phenyl Column to achieve excellent efficiency and lower operating back pressure when compared to completely porous particles of comparable particle size. This enables you to carry out techniques using conventional LC instruments while preserving effectiveness and resolution. Longer columns can be used to enhance resolution for co-eluting peaks in complex sample combinations.
Use the CORTECS Phenyl Column's alternate selectivity to C8 and C18 stationary phases to take advantage of analyte interactions with the benzyl ring. When utilizing methanol as the organic modifier, the variations in selectivity for this phase are especially noticeable for aromatic molecules. Moreover, the lab equipment will deliver exceptionally minimal column MS bleed, a long lifetime, and good peak form.
The CORTECS Phenyl Column packing materials are manufactured in a cGMP, ISO 9001 accredited facility using ultra-pure reagents and were developed specifically for use with the ACQUITY UPLC System. In order to guarantee exceptional, consistent performance, each batch of the CORTECS Phenyl Column packing material is chromatographically tested with acidic, basic, and neutral analytes. Each lab equipment is separately analyzed, and the results are given on the eCord Intelligent Chip in the form of a Performance Chromatogram and Certificate of Batch Analysis. The bonded phase batch number and the findings of the analytical tests are both listed on the Certificate of Analysis. The Performance Chromatogram, on the other hand, offers the batch number, column serial number, USP plate count, USP tailing factor, USP retention factor, and the chromatographic test conditions in addition to summarizing the performance of each particular column. According to Waters, these data sets ought to be documented and kept for later use.
We recommend that you also explore and invest in the TruView LCMS Certified Clear Glass 12 x 32 mm Screw Neck Vial, with Cap and Preslit PTFE/Silicone Septum, 2 mL Volume, 100/pk. The manufacturing and handling processes used to make TruView pH Control LCMS Certified Vials are strictly regulated. Mass spectrometers are used to check for cleanliness, and LC-MS/MS is used to check for low analyte adsorption.
What Is The pH Range Recommended For The CORTECS Phenyl Column?
The CORTECS Phenyl Column is able to conduct analyses between 2-8 pH.
What Are The Maximum Temperature Limits Of The CORTECS Phenyl Column?
The Waters CORTECS Phenyl Column listed here can tolerate a maximum of 45 C.