Chemistry |
Phenyl |
Separation Mode |
Reversed Phase |
Particle Substrate |
Silica |
pH Range Min |
2 pH |
pH Range Max |
8 pH |
Temperature Limits |
45 C |
Maximum Pressure |
18000 psi (1240 Bar) |
Endcapped |
Yes |
Bonding Technology |
Phenyl-Hexyl |
Silanol Activity |
Low |
Particle Shape |
Spherical |
Particle Size |
1.6 µm |
Endfitting Type |
Parker-style |
Pore Size |
90 Å |
Format |
Column |
Surface Area |
100 |
System |
UHPLC, UPLC |
Particle Technology |
Solid Core |
USP Classification |
L11 |
Inner Diameter |
2.1 mm |
Length |
100 mm |
Carbon Load |
5.9 % |
eCord |
Yes |
UNSPSC |
41115709 |
Brand |
CORTECS |
Product Type |
Columns |
Units per Package |
1 pk |
CORTECS Phenyl Column, 90Å, 1.6 µm, 2.1 mm X 100 mm, 1/pk
Opt for the Waters CORTECS Phenyl Column to lower operating back pressure and get high efficiency when compared to fully porous particles of similar particle size. This makes it possible for you to conduct methods with traditional LC instrumentation while maintaining efficiency and resolution. In complicated sample combinations, longer columns can be employed to improve resolution for co-eluting peaks.
Utilize alternative selectivity to C8 and C18 stationary phases offered by the CORTECS Phenyl Column due to analyte interactions with the benzyl ring. The selectivity differences for this phase are particularly noticed for aromatic compounds, especially when using methanol as the organic modifier. The lab equipment is also able to provide ultra-low column MS bleed, long lifetime, and excellent peak shape.
The CORTECS Phenyl Column packing materials were created expressly for use with the ACQUITY UPLC System and are made in a cGMP, ISO 9001 accredited facility with ultra-pure reagents. Each batch of the CORTECS Phenyl Column packing material is chromatographically tested with acidic, basic, and neutral analytes, with results held within narrow specification ranges to ensure outstanding, repeatable performance. On the eCordTM Intelligent Chip, a Performance Chromatogram and Certificate of Batch Analysis are provided after each column is independently examined. The Certificate of Analysis includes the bonded phase batch number as well as the analytical test results. The Performance Chromatogram, on the other hand, summarizes the performance of each individual column and provides the batch number, column serial number, USP plate count, USP tailing factor, USP retention factor, and the chromatographic test conditions. Waters recommends that these data sets should be recorded and saved for future reference.
You may also want to explore and invest in the CORTECS Phenyl VanGuard Pre-column, 90Å, 1.6 µm, 2.1 mm X 5 mm, 3/pk. The lab equipment has been designed to prevent any chemical or particulate matter from entering the mobile phase, and thus, improving the overall performance of the analytical column.
Is There A pH Limitation For The CORTECS Phenyl Column?
The CORTECS Phenyl Column listed here offers an operating pH range of 2 to 8. This is applicable if the pressure and temperature limits are followed as well.
What Is The Maximum Pressure That The CORTECS Phenyl Column Can Sustain?
The CORTECS Phenyl Column listed here is designed to withstand a maximum pressure of 18000 psi (1240 Bar).