Chemistry |
C18 |
Separation Mode |
Reversed Phase |
Particle Substrate |
Silica |
pH Range Min |
2 pH |
pH Range Max |
8 pH |
Temperature Limits |
45 C |
Maximum Pressure |
18000 psi (1240 Bar) |
Endcapped |
Yes |
Bonding Technology |
T3 |
Silanol Activity |
Low |
Particle Shape |
Spherical |
Particle Size |
2.7 µm |
Endfitting Type |
Parker-style |
Pore Size |
120 Å |
Format |
Column |
Surface Area |
100 |
System |
UHPLC, UPLC |
Particle Technology |
Solid Core |
USP Classification |
L1 |
Inner Diameter |
3 mm |
Length |
150 mm |
Carbon Load |
4.7 % |
eCord |
Yes |
UNSPSC |
41115709 |
Brand |
CORTECS |
Product Type |
Columns |
Units per Package |
1 pk |
CORTECS T3 Column, 120Å, 2.7 µm, 3 mm X 150 mm, 1/pk
CORTECS T3 columns are compatible with 100% aqueous mobile phases and offer high polar and non-polar analyte retention. When compared to completely porous particles of the same size, the particle shape delivers great efficiency and lower backpressure. CORTECS T3 has extremely low column MS bleed, long lifespans, and good peak form.
By including CORTECS T3 Column into your system, you will be able to achieve significantly higher efficiency and throughput simply by increasing the method's flow rate. One of the key benefits of the CORTECS T3 Column is that it enables you to speed up your analysis without affecting separation performance. This will allow you to process more samples in the same amount of time and receive faster results when utilizing the CORTECS T3 Column, lowering your overall lab equipment expenses and analysis time.
CORTECS T3 Columns were developed using Solid Core particle technology and are designed to work with any HPLC, UHPLC, or UPLC system. These CORTECS T3 columns are compatible with 100% aqueous mobile phases and provide excellent retention for both polar and non-polar analytes, making them a great asset to your laboratory equipment. In comparison to totally porous particles of similar size, the particle shape within the CORTECS T3 column allows for great efficiency and lower back-pressure. The CORTECS T3 column was designed with ultra-low MS bleed in mind, as well as superb peak form and a long column lifetime.
Waters ensures that our lab equipment is built in the strictest of quality control settings and to the highest industry standards, providing you with lab equipment you can trust. Each step of the CORTECS T3 Column manufacturing process is meticulously managed to ensure that you receive apparatus that will deliver consistent and repeatable results batch after batch and column after column.
You can browse through our catalog or through our website to review all of the offerings from Waters. You can shop for lab equipment as per your laboratory needs. You should also check out CORTECS T3 VanGuard Cartridge, 120Å, 2.7 µm, 2.1 mm X 5 mm, 3/pk; CORTECS T3 VanGuard Cartridges are used to extend analytical column lifetime and performance by removing particulate contamination from the mobile phase stream. This cartridge is optimized to protect all 2.1 mm and 3.0 mm I.D. CORTECS T3 analytical columns containing 2.7 µm sorbent particles.
What Is The Maximum Pressure That The CORTECS T3 Column Can Withstand?
The CORTECS T3 Column is built to sustain a pressure of 18000 psi (or 1240 bar) with a particle size of 1.6 m and a pore size of 120, although it is always recommended not to exceed the maximum range to guarantee the best possible column longevity and effectiveness.