SKU: 186008711
CORTECS Shield RP18 VanGuard Cartridge, 90Å, 2.7 µm, 3.9 mm X 5 mm, 3/pk

CORTECS Shield RP18 VanGuard Cartridge | 186008711


Streamline Purchasing with Customized Quotes

Streamline Purchasing with Customized Quotes

Shop on Waters.com and add items to your cart

Navigate to the Shopping Cart

Select Request a Quote to get your quote instantly


Product Description

CORTECS Shield RP18 VanGuard Cartridges are used to extend analytical column lifetime and performance by removing particulate contamination from the mobile phase stream. This cartridge is optimized to protect all 4.6 mm I.D. CORTECS Shield RP18 analytical columns containing 2.7 µm sorbent particles.

Specifications

  • Chemistry

    C18

  • Separation Mode

    Reversed Phase

  • Particle Substrate

    Silica

  • pH Range Min

    2 pH

  • pH Range Max

    8 pH

  • Maximum Pressure

    18000 psi (1240 Bar)

  • Endcapped

    Yes

  • Bonding Technology

    Shield RP18

  • Silanol Activity

    Low

  • Particle Shape

    Spherical

  • Particle Size

    2.7 µm

  • Endfitting Type

    Parker-style

  • Pore Size

    90 Å

  • Format

    VanGuard Cartridge

  • Surface Area

    100

  • System

    UHPLC, UPLC

  • Particle Technology

    Solid Core

  • USP Classification

    L1

  • Inner Diameter

    3.9 mm

  • Length

    5 mm

  • Carbon Load

    6.4 %

  • eCord

    Yes

  • UNSPSC

    41115709

  • Brand

    CORTECS

  • Product Type

    Guards

  • Units per Package

    3 pk

Product Support

Documents

Documents



What do you want to do?

What do you want to do?

Related Products

Back To Top Back To Top

CORTECS Shield RP18 VanGuard Cartridge, 90Å, 2.7 µm, 3.9 mm X 5 mm, 3/pk

CORTECS Shield RP18 VanGuard Cartridges are used to extend analytical column lifetime and performance by removing particulate contamination from the mobile phase stream. This cartridge is optimized to protect all 4.6 mm I.D. CORTECS Shield RP18 analytical columns containing 2.7 µm sorbent particles.

You may be confident that the CORTECS Shield RP18 VanGuard Cartridge will perform and protect your Waters analytical column for a long time because it is made with the same high-performance packing materials used in all of Waters analytical columns. The lab equipment was created specifically for scenarios requiring higher capacity for biological fluid purification and/or temperature control.

To protect your column from damage and extend its life, use the CORTECS Shield RP18 VanGuard Cartridge. Because the lab equipment is made of the same packing material as the CORTECS Shield RP18 column, it works perfectly with it. The cartridge is a piece of protective equipment that sits between the injector and the analytical column and keeps chemical contaminants and suspended particulates out of the analytical column.

You may want to explore our complete range of CORTECS lab equipment, available for purchase directly from our website.

Like all other Waters equipment, the CORTECS Shield RP18 VanGuard Cartridge is made in a cGMP, ISO 9001 certified plant utilizing ultra-pure reagents. Furthermore, each batch of CORTECS Shield RP18 VanGuard Cartridge packing material is chromatographically tested with acidic, basic, and neutral analytes, and the results are held to the highest standards to ensure good, repeatable performance. Furthermore, each cartridge is tested and approved for its intended usage, ensuring that it will function at its best and improve the selectivity, sensitivity, and speed of your study.

We recommend that you also explore the Neutrals QC Reference Material. The Neutrals QC Reference Material is intended for use with any UV-detector-equipped chromatographic equipment. It's meant to be used as a benchmarking standard for systems. Only neutral chemicals are present in the mixture. The QC Reference Material will provide confidence in your results, minimize troubleshooting and re-run time, and enable cross-laboratory result comparisons when used regularly and control tracked. This reference material can be separated using a variety of approaches.

What pH Range Is The CORTECS Shield RP18 VanGuard Cartridge Able To Work Across?

The CORTECS Shield RP18 VanGuard Cartridge listed here is able to work well across a minimum of 2 and a maximum of 8 pH.