Chemistry |
C18 |
Separation Mode |
Reversed Phase |
Particle Substrate |
Silica |
pH Range Min |
2 pH |
pH Range Max |
8 pH |
Temperature Limits |
45 C |
Maximum Pressure |
18000 psi (1240 Bar) |
Endcapped |
Yes |
Bonding Technology |
T3 |
Silanol Activity |
Medium |
Molecular Weight Range Min |
1000 |
Molecular Weight Range Max |
15000 |
Particle Shape |
Spherical |
Particle Size |
1.8 µm |
Endfitting Type |
Parker-style |
Pore Size |
100 Å |
QC Tested |
Peptide |
Format |
Column |
Surface Area |
230 |
System |
UHPLC, UPLC |
Particle Technology |
HSS |
USP Classification |
L1 |
Inner Diameter |
2.1 mm |
Length |
100 mm |
Carbon Load |
11 % |
UNSPSC |
41115709 |
Application |
Peptide |
Brand |
ACQUITY UPLC |
Product Type |
Columns |
Units per Package |
1 pk |
ACQUITY UPLC Peptide HSS T3 Column, 100Å, 1.8 µm, 2.1 mm X 100 mm, 1K - 15K, 1/pk
To satisfy a wide range of chromatographic applications, rely on the great value provided by the ACQUITY UPLC Peptide HSS T3 Column. The lab equipment makes it simple to switch methods while enhancing productivity and maintaining or increasing the resolution across components. Recognizing that the range of analyte polarity can make developing chromatographic methods problematic, Waters created the ACQUITY UPLC Peptide HSS T3 Column to allow a single chromatographic method to be used to examine a variety of formulation compositions. Because of the ACQUITY UPLC Peptide HSS T3 Column's remarkable characteristics, you will not only be able to meet the challenges of the laboratory, but you will also be more productive and successful in your work.
To handle the challenges of liquid chromatography with ease and confidence, add the ACQUITY UPLC Peptide HSS T3 Column to your lab equipment collection. The analytical column has a low ligand density and is ideally suited for reversed-phase liquid chromatography for better retention of polar chemicals and metabolites. The analytes will be able to reach the material's pore structure by using the ACQUITY UPLC Peptide HSS T3 Column. This eliminates the necessity for ion-pair reagents in the retention of polar and hydrophobic compounds.
The Waters HSS (High Strength Silica) particle technology used in the ACQUITY UPLC Peptide HSS T3 Column was developed specifically to withstand UPLC pressures by combining a mechanically tolerant silica-based material with an innovative synthetic process that significantly increases silica's mechanical stability. When compared to hybrid particle technology, this results in higher retentivity and alternative selectivity.
Because the ACQUITY UPLC Peptide HSS T3 Columns use Peptide Separation Technology (PST), which is based on BEH Technology particles, they meet the stringent BEH Technology particle criteria and are QC verified with a peptide map. As a result, well-developed peptide separations are stable, and many distinct samples utilized in proteomics, protein characterization, and peptide synthesis behave predictably. Over a wide range of peptide characteristics and application requirements, the surface chemistry produces crisp symmetrical peaks.
You may also want to explore the ACQUITY UPLC Peptide HSS T3 VanGuard Pre-column, 100Å, 1.8 µm, 2.1 mm X 5 mm, 1K - 15K, 3/pk.
What Is The pH Range Offered By The ACQUITY UPLC Peptide HSS T3 Column?
This particular ACQUITY UPLC Peptide HSS T3 Column offers a minimum of 2, and a maximum of 8 pH.
What Are The Temperature Limits Of The ACQUITY UPLC Peptide HSS T3 Column?
The ACQUITY UPLC Peptide HSS T3 Column is able to sustain up to 45 C.