Suggested Uses: Bottom-up Proteomics, Nano-flow, Trap and Elute
Chemistry |
C18 |
Separation Mode |
Reversed Phase |
Particle Substrate |
Hybrid |
pH Range Min |
1 pH |
pH Range Max |
10 pH |
Maximum Pressure |
15000 psi (1034 Bar) |
Endcapped |
Yes |
Silanol Activity |
Low |
Particle Shape |
Spherical |
Particle Size |
1.7 µm |
Endfitting Type |
10-32 for 1/16" male /360um open |
Pore Size |
130 Å |
QC Tested |
Peptide |
Format |
Column |
Surface Area |
185 |
System |
Nano/Micro |
Particle Technology |
CSH |
USP Classification |
L1 |
Inner Diameter |
75 µm |
Length |
150 mm |
Carbon Load |
15 % |
UNSPSC |
41115711 |
Application |
Peptide |
Brand |
nanoEase M/Z |
Product Type |
Columns |
Units per Package |
1 pk |
nanoEase M/Z Peptide CSH C18 Column, 130Å, 1.7 µm, 75 µm X 150 mm, 1/pk
For best performance in nano- to micro-scale liquid chromatographic separation, rely on the nanoEase M/Z Peptide CSH C18 Column. For biomarker discovery and protein identification and characterization, the lab equipment provides the highest possible sensitivity, resolution, and repeatability.
The nanoEase M/Z Peptide CSH C18 Column has an ultra-low dispersion design to provide the same ease of usage as more standard columns. The nanoEase M/Z Peptide CSH C18 Column, like other lab equipment with comparable chemistries, can withstand high working pressure and handle pressure changes during injection exceedingly well, resulting in an improved lifetime.
Waters' patented BEH Technology 130A pore, C18, 1.7µm particles are used in the nanoEase M/Z Peptide CSH C18 Column. This aids in achieving peak performance by ensuring adequate connections are established to reduce peak tailing and inefficiency.
Each batch of the nanoEase M/Z Peptide CSH C18 Column is QC tested using a gradient separation of a tryptic digest of cytochrome c before being QC accepted as a Peptide separation column to ensure you receive only the highest quality lab equipment.
The ZenFit Connectors that come pre-assembled with the nanoEase M/Z Peptide CSH C18 Column are designed to be utilized in V-detail style connection ports. The V-detail connection port is a 10-32 threaded port for 1/16" O.D. tubing that is easy to use, reusable, and fingertight. This simplifies the process of establishing essential nano- and microflow UPLC fluid connections. With the nanoEase M/Z Peptide CSH C18 Column, you can considerably eliminate flow-path-induced variability in chromatographic findings.
All of the nanoEase M/Z Peptide CSH C18 Column's versions and items that work with it can be found here. Shop for lab equipment and discover more about our brands and technologies on our website.
You may also be interested in the nanoEase M/Z HSS T3 Column, 100Å, 1.8 µm, 300 µm X 50 mm, 1/pk.
What pH Does The nanoEase M/Z Peptide CSH C18 Column Offer?
The nanoEase M/Z Peptide CSH C18 Column listed here offers a wide pH range of 1-10 pH.
What Is The Maximum Pressure That The nanoEase M/Z Peptide CSH C18 Column Can Tolerate?
The nanoEase M/Z Peptide CSH C18 Column is able to work well with up to 15000 psi (1034 Bar) pressure. However, it is recommended that the pressure be used less than the maximum limit so that the column lasts a longer time.