BioResolve SCX mAb VanGuard FIT Cartridge, 3 µm, 2.1 mm X 5 mm Waters VanGuard Fully Integrated Technology (FIT) Replacement Cartridges are packed with BioResolve SCX mAb, 3 µm particles. They are designed exclusively for use with the BioResolve SCX mAb, 3 μm Column with included VanGuard Fit option. VanGuard FIT replacement cartridges can ONLY be used on BioResolve SCX mAb COlumns that have VanGuard FIT component. This guard column is compatible with: p/n: 186009053 BioResolve SCX mAb Column with VanGuard FIT, 3 µm, 2.1 mm X 50 mm p/n: 186009055 BioResolve SCX mAb Column with VanGuard FIT, 3 µm, 2.1 mm X 100 mm p/n: 176004341 BioResolve SCX mAb Column with VanGuard FIT, 3 µm, 2.1 mm x 50 mm with mAb Charge Variant Standard p/n: 176004343 BioResolve SCX mAb Column with VanGuard FIT, 3 µm, 2.1 mm x 100 mm with mAb Charge Variant Standard
Temperature Limits |
60 C |
Maximum Pressure |
10000 psi (689 Bar) |
Bonding Technology |
SCX |
Particle Shape |
Spherical |
Particle Size |
3 µm |
QC Tested |
Protein |
Format |
Cartridge |
System |
HPLC, UHPLC, UPLC |
USP Classification |
L34 |
Inner Diameter |
2.1 mm |
Length |
5 mm |
UNSPSC |
41115712 |
Application |
Protein |
Brand |
BioResolve |
Product Type |
Cartridge Columns |
Units per Package |
3 pk |
BioResolve SCX mAb VanGuard FIT Cartridge, 3 µm, 2.1 mm X 5 mm, 3/pk
Performing monoclonal antibody separations and analyses can be hard work already. The last thing you want to worry about is your analytical column not working as it should because of internal fouling. To prevent the BioResolve SCX mAb Column from drops in performance caused by fouling, we’ve developed a solution with the BioResolve SCX mAb VanGuard FIT Cartridge. This guard cartridge seamlessly integrates into your existing workflow to provide enhanced protection from particulate contaminants. Worth noting here is that this cartridge is no replacement for proper sample purification protocols. It just helps remove any particulate contaminants that may be lingering in the mobile phase stream. Add the BioResolve SCX mAb VanGuard FIT Cartridge to your workflow now to enjoy increased protection and longer column lifetimes.
The BioResolve SCX mAb VanGuard FIT Cartridge is a reusable solution for the protection of your BioResolve SCX mAb Column. Once the cartridge becomes worn because of use, you can just switch it out with another. Make sure to properly inspect these cartridges before use, as you don’t want contaminants that were already there to infiltrate the inner lining of your column. What’s more, the BioResolve SCX mAb VanGuard FIT Cartridge offers the same inner diameter and pH range as the BioResolve SCX mAb Column, making for a chemically and mechanically stable column protection solution.
Before performing any mAb separations, make sure to verify proper LC-MS system performance. You can do so with the help of the mAb Charge Variant Standard. This LC-MS standard is specifically designed to help benchmark charge variant chromatography when using BioResolve SCX Columns. Plus, this standard contains a unique mix of intact proteins that many biopharma scientists will find familiar and welcoming, including tryptophan, conalbumin and the NIST RM 8671 (NIST mAb). Add the mAb Charge Variant Standard to your workflow and you’ll always be ready to verify system and instrument performance for charge-variant chromatography.
At Waters, it’s truly our passion to provide you with all the lab essentials. From quality control reference materials and lab informatics to full LC-MS systems and so much more, we truly have it all. Shop lab equipment to see everything we have to offer.
Which Column is the BioResolve SCX mAb VanGuard FIT Cartridge Designed to Protect?
The BioResolve SCX mAb VanGuard FIT Cartridge is designed to protect the BioResolve SCX mAb Column.