Waters Anionic Polar Pesticide Column has been designed specifically to provide quick, reproducible testing methods for highly anionic polar pesticides in agriculture products and finished foods. Polar pesticides such as Glyphosate can be challenging to analyze due to their zwitterionic properties and highly polar nature, however, the Anionic Polar Pesticide column provides application specific column chemistry for ease-of-use, quicker results and reliable low-level detection while maintaining key analyte separations.
Chemistry |
DEA |
Separation Mode |
Hydrophilic Interaction (HILIC) |
Particle Substrate |
Hybrid |
pH Range Min |
2 pH |
pH Range Max |
7 pH |
Particle Shape |
Spherical |
Particle Size |
5 µm |
Pore Size |
130 Å |
Format |
Column |
System |
UHPLC, UPLC |
Particle Technology |
BEH |
Technique |
LC/MS |
Inner Diameter |
2.1 mm |
Length |
100 mm |
eCord |
Yes |
UNSPSC |
41115709 |
Application |
Pesticides |
Brand |
Waters |
Product Type |
Columns |
Units per Package |
1 pk |
Anionic Polar Pesticide Column, 130Å, 5 µm, 2.1 mm x 100 mm, 1/pk
Use the Anionic Polar Pesticide Column to retain, separate, and analyze polar anionic compounds as it offers a winning combination of hydrophilic surface and the anion-exchange properties of ligands provides chromatographic characteristics well suited to the retention and separation of polar anionic compounds.
With the Anionic Polar Pesticide Column, you can analyze and separate highly anionic polar pesticides on HPLC, UHPLC, or UPLC instrumentation. This lab equipment has been specifically designed for excellent peak shape, with added selectivity for the analysis of various polar pesticides such as glyphosate operating under HILIC/WAX conditions and is based on new bonding technology used to create an adaptive selectivity platform.
The patent-pending bonding consists of a two-stage functionalization of chromatographic particles, starting with the ethylene bridged hybrid (BEH) particle. In the first step of the process, retention characteristics are controlled, while the second provides the unique selectivity of the phase.
The Anionic Polar Pesticide Column is manufactured in an ISO-certified plant using ultra-pure reagents, and the packing materials used are optimized for use with the ACQUITY™ UPLC Systems. In addition to this, each batch of particles is tested, and the results are held to narrow specification ranges to assure excellent, reproducible performance. You will also receive a Performance Chromatogram and Certificate of Batch Analysis with your Anionic Polar Pesticide Column. The information is included on the eCord Intelligent Chip.
Find out products that complement the product listed here and more variations of the same listing as well as slightly different specifications. You can read in detail about our products, our company, and our technology as well as shop for lab equipment throughout our catalog.
You may also be interested in the Anionic Polar Pesticide VanGuard Cartridge, 130Å, 5µm, 2.1 mm X 5 mm, 3/pk that can be used in conjunction with the analytical column and is designed to protect the column and enhance its lifetime. The cartridge is developed to remove particulate and chemical contaminants from the mobile phase to ensure that nothing interferes with your analysis and you get reliable and consistent results. This prolongs the life of the column and ensures that it does not need to be replaced soon.
What Temperature Range Is Suitable For The Anionic Polar Pesticide Column?
The recommended maximum operating temperature for the Anionic Polar Pesticide Column is 60° C with most common LC mobile phases and additives.