Chemistry |
RP/Anion-exchange |
Separation Mode |
Mixed mode |
Particle Substrate |
Hybrid |
pH Range Max |
10 pH |
Temperature Limits |
60 C |
Maximum Pressure |
18000 psi (1240 Bar) |
Endcapped |
Yes |
Bonding Technology |
C18 AX |
Silanol Activity |
Low |
Particle Shape |
Spherical |
Particle Size |
1.7 µm |
Endfitting Type |
Parker-style |
Pore Size |
95 Å |
Format |
Premier Column |
Surface Area |
270 |
System |
UHPLC, UPLC |
Particle Technology |
BEH |
Technique |
LC |
USP Classification |
L78 |
Inner Diameter |
2.1 mm |
Length |
50 mm |
Carbon Load |
17 % |
eCord |
Yes |
UNSPSC |
41115709 |
Brand |
Atlantis |
Product Type |
Columns |
Units per Package |
1 pk |
Atlantis Premier BEH C18 AX Column, 1.7 µm, 2.1 x 50 mm, 1/pk
Add the Waters Atlantis Premier BEH C18 AX Column to your lab equipment collection as it enables you to leverage excellent retention for polar acidic analytes under reversed-phase conditions. In addition to its reversed-phase/anion-exchange mixed-mode chemistry being stable from pH 2-10, the lab equipment has complementary selectivity to traditional C18 stationary phases that are available in the market, which is desirable when doing methods development.
The Atlantis Premier BEH C18 AX Column uses the MaxPeak™ High-Performance Surfaces, an innovative technology that has been specifically designed to increase analyte recovery, sensitivity, and reproducibility by minimizing analyte/surface interactions that can cause significant sample losses. The Atlantis PREMIER BEH C18 AX Column not only gives reliable, consistent analysis results, but it is also highly efficient and enables you to prepare and use as many samples as required, making it a crucial addition to any analytical lab.
You can search through our online catalog that details all the inventory available in the Waters portfolio. You can easily find and purchase lab equipment that works in conjunction with the Atlantis PREMIER BEH C18 AX Column using the online store. Like all our lab equipment, the Atlantis Premier BEH C18 AX Column packing material is manufactured in a cGMP, ISO 9001 certified plant using ultra-pure reagents. Further, to be certain that the equipment you receive from us has high-quality standards, each batch is tested chromatographically, and the results are held to narrow specification ranges.
After each Atlantis Premier BEH C18 AX Column undergoes the individual testing, a Performance Chromatogram and Certificate of Batch Analysis are included in the column box or on the eCord™ Intelligent Chip. The Certificate of Analysis is specific to each batch of packing material which includes the batch number, analysis of unbonded particles, analysis of bonded particles, and chromatographic results and conditions. The Performance Test Chromatogram is also specific to each individual column and contains the batch number, column serial number, USP tangent efficiency, USP tailing factor, retention factor, and chromatographic conditions. Waters recommends that these data should be stored for future reference. If you are unable to access the information on the eCord Intelligent Chip, the Certificate of Analysis, and Performance Test Chromatogram, you can request the information from our website.
You may also want to explore the LCMS Certified Clear Glass 12 x 32 mm Screw Neck Total Recovery Vial, with Cap and Preslit PTFE/Silicone Septum, 1 mL Volume, 100/pk.
What Is The Maximum Pressure That The Atlantis Premier BEH C18 AX Column Works With?
The Atlantis Premier BEH C18 AX Column listed here can work with pressures of up to 18,000 psi (1240 Bar).